Procedure 5-55: Clear
″
VCG Loss of Partial Capacity
″
alarm
....................................................................................................................................................................................................................................
Overview
This procedure is used to clear a
VCG Loss of Partial Capacity
alarm indicated by a lighted minor (
MN/ABN
) LED on the local
SYSCTL faceplate, and reported as minor in the WaveStar
®
CIT
Alarm List.
Before you begin
Prior to performing this procedure:
1.
Refer to
and
in this chapter.
2.
Refer to
and
“Electrostatic discharge” (1-13)
in
Procedure
Complete the following steps to clear a
VCG Loss of Partial
Capacity
alarm.
............................................................................................................................................................
1
From the WaveStar
®
CIT System View, click the
Alarm List
button
and locate the
VCG Loss of Partial Capacity
alarm in the
resulting alarm list.
............................................................................................................................................................
2
Are there other inc. OCN, STSN, or VT1.5 alarms in the alarm list
affecting tributaries in the specified VCG?
If...
Then...
Yes
Proceed to the appropriate procedure
to clear the alarm. Then continue with
No
Continue with
............................................................................................................................................................
3
From the System View, click the
Alarm List
button and click
Refresh
.
Trouble clearing procedures
....................................................................................................................................................................................................................................
5 - 1 5 6
Lucent Technologies
365-372-333 R2.1
Issue 4, June 2005