illegal CP type
....................................................................................................................................................................................................................................
illegal CP type
An unsupported circuit pack type is present in a slot.
Alarm Data
Value/Meaning
Reported Alarm
Level(s)
Critical (CR), Minor (MN)
AID (type)
Slot
Date
month/day/year that condition was detected
Time
hour:minute:second that condition was detected
Probable Cause
FACTERM
Effect on
Service
CR = SA
MN = NSA
Alarm Entity
Type
EQPT
Description
illegal CP type
Likely Cause
A slot was occupied and provisioned for a
supported circuit pack type. The supported circuit
pack was removed and an unsupported circuit
pack type was inserted into that slot: CR (SA).
An illegal or unknown circuit pack type has been
inserted into the shelf: MN (NSA).
Visible
indication
Lighted
CR/MJ
or
MN/ABN
LED on SYSCTL
faceplate and a continuously lighted
FAULT
LED
on the alarmed circuit pack.
Action
Proceed to
Alarms, conditions, and error messages
....................................................................................................................................................................................................................................
365-372-333 R2.1
Issue 4, June 2005
Lucent Technologies
3 - 3 5