Procedure 5-29: Clear
″
inc. OCN
″
conditions/alarms
....................................................................................................................................................................................................................................
Overview
This procedure is used to clear all
inc. OCN
alarms, including:
•
inc. OCN line AIS
•
inc. OCN LOF
•
inc. OCN LOS
•
inc. OCN sig. degrade (BER)
•
inc. OCN sig. failed (BER)
Refer
and
Chapter 3, “Alarms, conditions, and
for the possible alarm levels for the different alarms.
Before you begin
Prior to performing this procedure:
1.
Refer to
and
in this chapter.
2.
Refer to
and
“Electrostatic discharge” (1-13)
in
Procedure
Complete the following steps to clear an
inc. OCN
condition/alarm.
............................................................................................................................................................
1
From the WaveStar
®
CIT System View, click the
Alarm List
button
and locate the
inc. OCN
condition/alarm in the resulting alarm list.
............................................................................................................................................................
2
Determine the alarm level(s) for the active
inc. OCN
alarm(s) (for
example, CR, MJ, or MN). Clear the alarms in order of severity, CR,
(SA), MJ (SA), MJ (NSA), MN (NSA), and then Not Alarmed.
............................................................................................................................................................
3
Refer to the Probable Cause column in the alarm list, determine the
OC-N line affected by the
inc. OCN
alarm, and note the
corresponding AID.