Procedure 5-8: Clear
″
dormant/exec code mismatch
″
condition
....................................................................................................................................................................................................................................
Overview
This procedure is used to clear a
dormant/exec code mismatch
condition, reported as a Standing Condition (SC) in the WaveStar
®
CIT Alarm List.
Before you begin
Prior to performing this procedure:
1.
Refer to
and
in this chapter.
2.
Refer to
“Electrostatic discharge” (1-13)
in
Procedure
Complete the following steps to clear a
dormant/exec code
mismatch
condition.
............................................................................................................................................................
1
From the System View menu, select
Configuration
→
Software
→
Apply Software
.
Result:
The Apply Software window opens.
............................................................................................................................................................
2
Select and/or enter the following information in the Apply Software
window:
1.
From the
Available Generics
panel, select the software generic
to be activated.
2.
From the
Activation Scheduling
panel, you may schedule the
activation time and date in one of the following ways:
•
Select
Install Immediately
. The software will install as soon
as possible after clicking
OK
and accepting the warning
screen.
This install option cannot be cancelled.
•
Select
Install In 15 Minutes
. The software will install 15
minutes after you click
OK
.
•
Select
Specify Install Date/Time
and select the
Year
,
Month
,
Date
and
Time
.
Trouble clearing procedures
....................................................................................................................................................................................................................................
5 - 3 2
Lucent Technologies
365-372-333 R2.1
Issue 4, June 2005