6
Is the correct circuit pack type physically installed in the required
slot?
If...
Then...
Yes,
Perform the following:
1. Select
View
→
Cross-Connection
. Click on
the required circuit pack and
Select
to obtain a list of
provisioned cross-connections
for the circuit pack.
2. If required, select
Configuration
→
Cross-Connection
to access
the Cross-Connection Wizard
and delete any existing
cross-connections to the
circuit pack.
3. Select
Configuration
→
Update System
→
Update All
.
A dialog box appears asking
you to confirm executing this
command. Click
Yes.
No,
Perform the following:
1. Obtain the correct type of
circuit pack (according to
office records) for the
required slot.
2. Replace the wrong circuit
pack currently in the required
slot with the correct circuit
pack. Refer to the
appropriate circuit pack
replacement procedure in
Chapter 6, “Supporting
procedures”
Procedure 5-52: Clear
″
unexpected CP type
″
alarm
Trouble clearing procedures
....................................................................................................................................................................................................................................
5 - 1 4 8