3
Is fan unit powered and running properly? The Metropolis
®
DMXplore fan unit needs three fans operating to provide the
minimum required airflow.
If...
Then...
Yes
STOP! End of Procedure.
No
Continue with
............................................................................................................................................................
4
Is the red Fault (
FAN FAULT
) LED lighted on the fan unit?
If...
Then...
Yes
Continue with
No
Proceed to
............................................................................................................................................................
5
From the System View, click the
Alarm List
button and click
Refresh
.
............................................................................................................................................................
6
Are any other alarms present?
If...
Then...
Yes
Proceed to the appropriate procedure
to clear the other alarm(s).
No
Proceed to
............................................................................................................................................................
7
Is the fan unit running and working properly (
PWR ON
LEDs lighted,
FAN FAULT
LED off)?
If...
Then...
Yes
STOP! End of Procedure.
Procedure 5-17: Clear
″
fan shelf failed
″
alarm
Trouble clearing procedures
....................................................................................................................................................................................................................................
365-372-333 R2.1
Issue 4, June 2005
Lucent Technologies
5 - 5 3