CP software upgrade required
....................................................................................................................................................................................................................................
CP software upgrade
required
The firmware in the indicated circuit pack does not match the active
software generic running on the NE.
Alarm Data
Value/Meaning
Reported Alarm
Level(s)
Not Alarmed
AID (type)
Slot
Date
month/day/year that condition was detected
Time
hour:minute:second that condition was detected
Probable Cause
FACTERM
Effect on
Service
Standing Condition (SC)
Alarm Entity
Type
COM
Description
CP software upgrade required
Likely Cause
A new version of the software generic was applied
to the shelf and indicated circuit pack did not
update automatically or a new circuit pack was
inserted into the shelf and the active software
generic on the shelf does not match the new
circuit pack.
Visible
indication
Lighted
MN/ABN
LED on SYSCTL faceplate.
Action
Proceed to
Alarms, conditions, and error messages
....................................................................................................................................................................................................................................
365-372-333 R2.1
Issue 4, June 2005
Lucent Technologies
3 - 1 5