Procedure 5-7: Clear
″
CP software upgrade required
″
condition
....................................................................................................................................................................................................................................
Overview
This procedure is used to clear a
CP software upgrade required
condition indicated by a lighted Abnormal (
MN/ABN
) LED on the
SYSCTL faceplate and reported as a Standing Condition (SC) in the
WaveStar
®
CIT Alarm List.
Before you begin
Prior to performing this procedure:
1.
Refer to
and
in this chapter.
2.
Refer to
“Electrostatic discharge” (1-13)
in
Procedure
Complete the following steps to clear a
CP software upgrade
required
condition.
............................................................................................................................................................
1
From the WaveStar
®
CIT System View, click the
Alarm List
button
and locate the CP software upgrade required alarm in the resulting
alarm list.
............................................................................................................................................................
2
Refer to the Probable Cause column in the alarm list, determine the
circuit pack affected, and note the corresponding AID.
............................................................................................................................................................
3
Un-seat and then re-seat the alarmed circuit pack.
Result:
SYSCTL reinitializes the pack and should
automatically update the firmware on the newly installed
pack.
............................................................................................................................................................
4
From the WaveStar
®
CIT System View, click the
Alarm List
button
and click
Refresh
.
............................................................................................................................................................
5
Is the
CP software upgrade required
alarm still present?
If...
Then...
Yes
Continue with
Trouble clearing procedures
....................................................................................................................................................................................................................................
5 - 2 6
Lucent Technologies
365-372-333 R2.1
Issue 4, June 2005