5
Compare the correct circuit pack information from the Circuit Pack
List with the circuit pack that is physically in the required slot.
If the circuit packs...
Then...
are the same type,
Perform the following:
1. Select
View
→
Cross-Connection
.
Click on the required circuit pack
and
Select
to obtain a list of
cross-connections. Observe the
provisioned cross-connections for
the required circuit pack and
compare with office records.
2. Select
Configuration
→
Cross-Connection
to access the
Cross-Connection Wizard and make
the required cross-connections
changes to/from the circuit pack.
are not the same type,
Perform the following:
1. Obtain the correct type of circuit
pack (according to the Circuit Pack
List) for the required slot.
2. Replace the wrong circuit pack
currently in the required slot with
the correct circuit pack. Refer to
the appropriate circuit pack
replacement procedure in
............................................................................................................................................................
6
From the System View, click the
Alarm List
button and click
Refresh
.
Procedure 5-4: Clear
″
CP not allowed - crs
″
alarm
Trouble clearing procedures
....................................................................................................................................................................................................................................
5 - 1 8
Lucent Technologies
365-372-333 R2.1