System Controller test
The system controller test performs a basic sanity check of the system
controller on the SYSCTL circuit pack. The test results in a pass/fail
indication of the processor’s health.
Use the
test-sysctl
command or select
Fault
→
Test
→
System
Controller
from the WaveStar
®
CIT System View menu to test the
system controller.
Transmission test
Metropolis
®
DMXplore provides internal testing capabilities for
installation and manual troubleshooting. DS1 and DS3 test signal
generators and detectors are integrated in the system, eliminating the
need for external test equipment to do DS1 and DS3 transmission
testing.
Specific signals and system components may be tested. For example,
technicians can manually enable the integrated test signal generators
and detectors for DS1 and DS3 low-speed interfaces.
Use the
test-trmsn
command or select
Fault
→
Test
→
Transmission
from the WaveStar
®
CIT System View menu to test
transmission.
Additional popup screens are used to facilitate the specific
transmission tests.
Tests
Maintenance overview
....................................................................................................................................................................................................................................
4 - 2 4
Lucent Technologies
365-372-333 R2.1
Issue 4, June 2005