Procedure 5-4: Clear
″
CP not allowed - crs
″
alarm
....................................................................................................................................................................................................................................
Overview
This procedure is used to clear a
CP not allowed - crs
alarm
indicated by a lighted Critical (
CR/MJ
) or Minor (
MN/ABN
) LED on
the SYSCTL faceplate and reported as critical or minor in the
WaveStar
®
CIT Alarm List.
Before you begin
Prior to performing this procedure:
1.
Refer to
and
in this chapter.
2.
Refer to
and
“Electrostatic discharge” (1-13)
in
Procedure
Complete the following steps to clear a
CP not allowed - crs
alarm.
............................................................................................................................................................
1
From the WaveStar
®
CIT System View, click the
Alarm List
button
and locate the
CP not allowed - crs
alarm in the resulting alarm
list.
............................................................................................................................................................
2
Determine the alarm level(s) for the active
CP not allowed - crs
alarm(s) (for example, CR or MN). Clear the alarms in order of
severity, CR (SA) and then MN (NSA).
Important! The
CP not allowed - crs
alarm is either CR (SA)
when the circuit pack is active (either working and unprotected
or the protection switch failed) or MN (NSA) when the circuit
pack is protected and protection switch operated normally.
............................................................................................................................................................
3
Refer to the Probable Cause column in the alarm list, determine the
circuit pack affected, and note the corresponding slot AID.
............................................................................................................................................................
4
Select
Reports
→
Equipment Lists
→
Pack
. Click on Shelf and
Select
to obtain the Circuit Pack List. Observe the correct circuit
pack information for the required slot.
Trouble clearing procedures
....................................................................................................................................................................................................................................
365-372-333 R2.1
Issue 4, June 2005
Lucent Technologies
5 - 1 7