If...
Then...
correct pluggable
transmission module was
installed in the wrong
socket/circuit pack,
Perform the following:
1. Remove the pluggable transmission
module from the wrong
socket/circuit pack and install the
pluggable transmission module in
the correct socket/circuit pack.
(Refer to
pluggable transmission module”
(6-203)
2. Select
Configuration
→
Update
System
→
Update Inventory
to
update the system equipment list.
3. Continue with
wrong pluggable
transmission module was
installed in the correct
socket/circuit pack,
Perform the following:
1. Replace the wrong pluggable
transmission module with the
correct pluggable transmission
module. (Refer to
Replace pluggable transmission
module” (6-203)
2. Select
Configuration
→
Update
System
→
Update Inventory
to
update the system equipment list.
3. Continue with
............................................................................................................................................................
7
From the System View, click the
Alarm List
button and click
Refresh
.
Procedure 5-53: Clear
″
unexpected or failed
Pluggable Transmission Module
″
alarm
Trouble clearing procedures
....................................................................................................................................................................................................................................