Procedure 6-14: Replace pluggable transmission module
....................................................................................................................................................................................................................................
Overview
Use this procedure to replace a pluggable transmission module in a
circuit pack.
Required equipment
Use only the following Lucent Approved Class 1 SFP transceivers.
Name
Qualifier
Pluggable
Transmission Module
Code/Comcode
Description
OMFE
100BASE-LX-SM
100BASE-LX-I1
109527812
100 Mb/s optical Fast
Ethernet SFP TRCVR
Refer to the Metropolis
®
DMXplore Access Multiplexer Installation
Manual, 365-372-334, as required, when removing and/or installing
pluggable transmission modules.
Before you begin
Prior to performing this procedure:
1.
Refer to
and
“Electrostatic discharge” (1-13)
information in
2.
Using office records and/or
View
→
Equipment
, determine the
correct type of pluggable optical module to be replaced.
3.
Ensure that the correct pluggable optical module is available for
replacement.
Procedure
Complete the following steps to replace a pluggable transmission
module.
............................................................................................................................................................
1
Remove the optical cables from the required pluggable transmission
module.
Supporting procedures
....................................................................................................................................................................................................................................
365-372-333 R2.1
Issue 4, June 2005
Lucent Technologies
6 - 2 0 3