19
Is the
VCG Loss of Partial Capacity
alarm still present?
If...
Then...
Yes
Continue with
No
STOP! End of Procedure.
............................................................................................................................................................
20
CAUTION
Service disruption hazard
Disconnecting cables and/or replacing circuit packs may disrupt
service.
Before taking action, determine the extent of service disruption
caused by disconnecting cables or replacing a circuit pack. Then,
perform the action(s) deemed appropriate in light of the traffic
being carried and the nature of the failure.
Replace the near-end Ethernet circuit pack.
Reference:
“Procedure 6-5: Replace Ethernet circuit pack”
............................................................................................................................................................
21
From the System View, click the
Alarm List
button and click
Refresh
.
............................................................................................................................................................
22
Is the
VCG Loss of Partial Capacity
alarm still present?
If...
Then...
Yes
Contact your next level of support.
No
STOP! End of Procedure.
E
N D
O F
S
T E P S
..............................................................................................................................................................................
Procedure 5-55: Clear
″
VCG Loss of Partial
Capacity
″
alarm
Trouble clearing procedures
....................................................................................................................................................................................................................................
5 - 1 6 0
Lucent Technologies
365-372-333 R2.1