Procedure 5-20: Clear
″
forced switch
″
condition
....................................................................................................................................................................................................................................
Overview
This procedure is used to clear a
forced switch
condition indicated
by a lighted Abnormal (
MN/ABN
) LED on the SYSCTL faceplate, and
reported as a Standing Condition (SC) in the WaveStar
®
CIT Alarm
List.
Before you begin
Prior to performing this procedure, refer to
and
in this chapter.
Procedure
Complete the following steps to clear a
forced switch
condition.
............................................................................................................................................................
1
From the WaveStar
®
CIT System View, click on the
Alarm List
button and locate the
forced switch
condition in the resulting alarm
list and note the corresponding AID.
............................................................................................................................................................
2
From the System View menu, select
Fault
→
Protection Switch
,
highlight the appropriate Protection Group, and then click
Select
.
Result:
On the right side of the Switch Protection window,
the Switch Type: pull-down menu appears.
............................................................................................................................................................
3
From the Switch Type: pull-down menu, select
Reset
and click
Apply
.
Result:
A warning message appears asking you to confirm
executing this command.
............................................................................................................................................................
4
Click
Yes
to release the forced switch. Click
Close
to exit the Switch
Protection window.
............................................................................................................................................................
5
From the System View, click the
Alarm List
button and click
Refresh
.