15
Is the
Member Signal Unacceptable-LCAS
alarm still present?
If...
Then...
Yes
Continue with
No
STOP! End of Procedure.
............................................................................................................................................................
16
From the System View menu, select
Fault
→
Reset
→
System
Controller
.
Result:
The Reset System Controller window opens.
............................................................................................................................................................
17
Click Reset the system software without changing parameters (Phase
3). Phase 9 should never be selected if the system is in-service. If
desired, click
History Log
and/or
Security Log
to save the network
element History and/or Security Logs. Click
OK
.
Important! The network element logs will be lost when the
controller is reset unless you choose to save the logs.
Result:
A warning appears asking you to confirm executing
this command.
............................................................................................................................................................
18
Click
Yes
to execute the command.
Important! You will be logged off the system when the system
resets.
Result:
You are logged off the system.
............................................................................................................................................................
19
From the System View, click the
Alarm List
button and click
Refresh
.
............................................................................................................................................................
20
Is the
Member Signal Unacceptable-LCAS
alarm still present?
If...
Then...
Yes
Continue with
Procedure 5-41: Clear
″
Member Signal
Unacceptable - LCAS
″
alarm
Trouble clearing procedures
....................................................................................................................................................................................................................................
365-372-333 R2.1
Issue 4, June 2005
Lucent Technologies
5 - 1 2 3