19
From the System View window, select
Configuration
→
Update
System
→
Update All
.
Result:
The port LED stops flashing. All alarms are cleared.
............................................................................................................................................................
20
From the System View window, click the
Alarm List
button to obtain
the NE Alarm List and verify that no alarms are present for the port
on the pluggable transmission module just installed.
If required, refer to the appropriate procedure to clear any alarms
present for the required port.
............................................................................................................................................................
21
From the System View menu, use
View
→
Equipment
to access the
port parameters for the pluggable transmission module just installed
and verify that the parameters are intact.
If required, refer to the appropriate procedure in the Metropolis
®
DMXplore Access Multiplexer User Operations Guide, 365-372-332 to
change any port parameters.
E
N D
O F
S
T E P S
..............................................................................................................................................................................
Procedure 6-14: Replace pluggable
transmission module
Supporting procedures
....................................................................................................................................................................................................................................
365-372-333 R2.1
Issue 4, June 2005
Lucent Technologies
6 - 2 1 3