4
From the System View menu, select
Configuration
→
DCC
Terminations
.
Result:
The Configure DCC Terminations window opens.
............................................................................................................................................................
5
From the Configure DCC Terminations window,
1.
Under DCC Termination Parameters
→
DCC Port, select the Port
AID that you wish to reprovision.
2.
Under DCC Channel Parameters
→
Termination State, select
enabled
.
3.
Under DCC Channel Parameters
→
LAPD Role, select
user-side
or
network-side
. (LAPD = link access protocol of the
D-channel)
4.
Click
Apply
.
5.
Click
Close
on the Configure DCC Terminations window.
6.
Proceed to
............................................................................................................................................................
6
From the System View, click the
Alarm List
button and click
Refresh
.
............................................................................................................................................................
7
Is the
section DCC channel failed
alarm still present?
If...
Then...
Yes
Continue with
No
STOP! End of Procedure.
............................................................................................................................................................
8
Check optical connections for the presence of an incoming signal.
............................................................................................................................................................
9
Check the optical signal level and clean the cable ends if needed. If
no problem is found, check the line build-outs (LBOs).
Procedure 5-50: Clear
″
section DCC
channel failed
″
alarm
Trouble clearing procedures
....................................................................................................................................................................................................................................
365-372-333 R2.1
Issue 4, June 2005
Lucent Technologies
5 - 1 4 3