Procedure 5-15: Clear
″
environmentn
″
alarm
....................................................................................................................................................................................................................................
Overview
This procedure is used to clear an
environmentn
alarm reported in
the WaveStar
®
CIT Alarm List as Critical, Major, Minor (Default), or
Not Alarmed. The alarm list identifies the affected environmental
input as 1 through 4. In the rack-mounted version of the Metropolis
®
DMXplore shelf, 5 is always the fan.
Before you begin
Prior to performing this procedure, refer to
and
in this chapter.
Procedure
Complete the following steps to clear an
environmentn
alarm/condition.
............................................................................................................................................................
1
From the WaveStar
®
CIT System View, click on the
Alarm List
button and locate the
environmentn
alarm/condition in the resulting
alarm list.
............................................................................................................................................................
2
Determine the alarm level(s) for the active
environmentn
alarm(s).
Clear the alarms in order of severity, CR (SA), MJ (SA), MN (NSA),
and then Not Alarmed.
............................................................................................................................................................
3
Refer to the Probable Cause column in the alarm list and note the
corresponding AID.
............................................................................................................................................................
4
From the System View menu, select
View
→
Misc. Discretes
and
expand
Input
.
Result:
The View Miscellaneous Discretes window opens.
............................................................................................................................................................
5
Can you clearly identify the cause of the condition?
If...
Then...
Yes
Click
Close
on the View Miscellaneous
Discretes window.
Clear using local procedures. Continue
with
Trouble clearing procedures
....................................................................................................................................................................................................................................
365-372-333 R2.1
Issue 4, June 2005