Raisecom Technology Co., Ltd
RC3000 PCM Multi-Service
Multiplexer
User Manual
(
9/2005
)
Page 1: ...Raisecom Technology Co Ltd RC3000 PCM Multi Service Multiplexer User Manual Raisecom Technology Co Ltd 9 2005...
Page 2: ...that has precise elements please avoid violent shakes and impacts and do not disassemble or maintain the device yourself If it is required please do it under the guide of our technical staff followin...
Page 3: ...RC3000 SUB DS 16 5 2 2 Interface standard of FXO voice relay user board RC3000 SUB DO 17 5 2 3 Interface standard of E M 2 audio relay user board RC3000 SUB DM2 17 5 2 4 Interface standard of E M 4 a...
Page 4: ...hannel explanation 31 7 1 9 Interface definitions 32 7 2 RC3000 SUB DS user voice card explanation 34 7 3 RC3000 SUB DO voice relay card explanation 35 7 4 RC3000 SUB DSO user board explanation 36 7 5...
Page 5: ...configure RC3000 52 10 1 Enter 52 10 2 Input the password 53 10 3 Main menu 54 10 4 Device set query 54 10 4 1 Device ID and Baud rate 54 10 4 2 Line Board information RAM 55 10 4 3 Line Board inform...
Page 6: ...11 3 Mask Set 72 10 11 4 CRC Set 73 10 12 User Board Set with signal menu 73 10 12 1 Input Signal 73 10 12 2 Output Signal 73 10 12 3 Signal Bit 74 10 13 V35 User Board Set menu 74 10 13 1 Sub Board...
Page 7: ...ar All Set 81 10 17 4 Clear Cross Set 82 10 17 5 Save Set Info 82 10 17 6 Make Default Set 82 10 17 7 Clear Reset and Board Change Flag 82 10 17 8 Test Watchdog 82 10 17 9 Test EEPROM 82 10 18 Version...
Page 8: ...ss application and can save both devices and money for our costumers z Use large integrated circuit module and programmable logic circuit and there are multi kinds of check methods in control program...
Page 9: ...Raisecom Technology Co Ltd 8 z Strong network management function both assistant network management channel and network management cascade are available to manage whole network of RC3000 devices...
Page 10: ...the same timeslots In simple application with proper user board the devices can start to work without any configuration In this case RC3000 does not use its function of cross connect and add drop voic...
Page 11: ...n remote are corresponding to each other and the local device can allot service to the three remote ones Meanwhile work status of middle device will not affect the last device 3 3 Multi devices ADM ap...
Page 12: ...int to multipoint star topology application Point to multipoint acess through RC3000 4E1 in figure 5 This application can reduce the number of devices for multi user service configuration 3 5 Hybrid a...
Page 13: ...and RC3000 2E1 ADM have two CC3 coaxial cable 3 E1 interfaces and RC3000 2E1 ADM function For RC3000 OPT the optical module type decides the device type as following table Device type Optical module t...
Page 14: ...tion RC3000 SUB DS FXS user voice user board 8 channels unconfigurable RC3000 SUB DO FXO voice relay user board 8 channels unconfigurable RC3000 SUB DSO FXS and FXO hybrid voice user board 8 channels...
Page 15: ...RC3000 SUB D422 RS422 serial data user board 8 channels unconfigurable RC3000 SUB DMT Magneto telephone user board 8 channels unconfigurable RC3000 SUB DSR FXS user board with polarity reversal funct...
Page 16: ...nger than 200m 0 6mm 22AWG twisted pair is recommended for balanced signal PCM30 and PCM31 are both available 5 1 2 Optical fiber parameters Standard rate 150Mbps Interface coding Special coding Optic...
Page 17: ...00m Comply with IEEE 802 3 10 100M auto negotiation full half duplex auto negotiation Support IEEE 802 1d Spanning Tree relay IEEE 802 1q VLAN packet relay Maximum Ethernet frame size is 1916 byte Sup...
Page 18: ...ristic from 2W to 4W hangup status 0 0 2 db Gain from 2W to 4W pickup status 0 0 5 db Frequency characteristic from 2W to 4W pickup status 0 0 2 db Gain from 4W to 2W pickup status 3 5 0 5 db Frequenc...
Page 19: ...Output loop impedance 600 Input loop impedance 600 Blance 60 db Maximum voltage of common mode 300 V Common Mode Rejection Ratio 60 db Power supply Rejection Ratio 30 db Idle channel noise 60 db Note...
Page 20: ...n full duplex Support flow contrla of backpressure in half duplex MDI and MDIX auto sensing 5 2 8 Interface standard of RS232 serial data user board RC3000 SUB D232 Physical characteristic RS232 inter...
Page 21: ...tandard of FXS user board with polarity reversal function RC3000 SUB DSR Feed voltage DC 48 V or DC 24 V Loop current 18 24 mA standard value 20 mA Feed ring voltage AC 65 10 V 25 Hz Ring stop time 20...
Page 22: ...Raisecom Technology Co Ltd 21 5 4 Environment requirement Temperature 0 50 Relative humidity 90 25 noncondensing...
Page 23: ...data or voice access RC7850 module cross connect the user information to up link interface or up link data to user interface through cross matrix Memory module save all kinds of user configuration inc...
Page 24: ...mal work status MPU will collect information of line board module user board module RC7850 module and alarm continuously and control all the modules MPU also answers user queries receives configuratio...
Page 25: ...g data 6 2 2 Indicator lights of line board 4E1 green ON line board is 4E1 interface card 2E1 green ON line board is 2E1 interface card OPT green ON line board is optical interface card Note only one...
Page 26: ...his button only mutes the present sound And if there are new alarms there will be new alarm sound CONSOLE A RJ45 connector to connect PC and RC3000 device for Hyper Terminal configuration through the...
Page 27: ...the device in this case LINK DOWN interface is still available for cascade The last bit is reserved Note in a physical network of RC3000s only one network management PC is available or you cannot man...
Page 28: ...fixed and not hot swap 1 Optical line board 100M Ethernet interface RC3000 OPT FE 2 Optical line board 2E1 interfaces RC3000 OPT 2E1 3 Line board with unbalanced 2 E1 interfaces RC3000 2E1 4 Line boar...
Page 29: ...device 7 1 3 System automatic configuration in factory default status RC3000 will configure itself according to hardware Configuration information not related to line board a Device ID not configured...
Page 30: ...ard s channels with those of first user E1 channels 1 8 one by one according to user board channel number note this number should be equal or less than 8 if the user board channel number is configurab...
Page 31: ...6 Explanation of system configuration and cross connect configuration RC3000 has rich configuration information for any E1 interface and signal interface to realize all kinds of cross connect Please...
Page 32: ...e Work status of fan f Channel configuration information for each user board 7 1 8 Network management channel explanation Network management channel explanation RC3000 has both assistant network manag...
Page 33: ...de Local and remote network management channel connection can be realized through LINK UP and LINK DOWN interfaces on RC3000 as in figure 20 There are three RC3000 networks RC3000 A and RC3000 B conne...
Page 34: ...inition Network management interface LINK DOWN is RC45 interface and standard RC232 voltage Signaling and Pinouts Pin number Signal Explanation 3 TXD Rx of RC3000 7 RXD Tx of RC3000 4 8 GND Ground of...
Page 35: ...is as follows Channel 1 2 3 4 Pins RJ45 1 1A 2B RJ45 1 3A 4B RJ45 1 5A 6B RJ45 1 7A 8B Channel 5 6 7 8 Pins RJ45 2 1A 2B RJ45 2 3A 4B RJ45 2 5A 6B RJ45 2 7A 8B Fundamental structure of RC3000 SUB DS 1...
Page 36: ...erface is as follows Channel 1 2 3 4 Pines RJ45 1 1A 2B RJ45 1 3A 4B RJ45 1 5A 6B RJ45 1 7A 8B Channel 5 6 7 8 Pins RJ45 2 1A 2B RJ45 2 3A 4B RJ45 2 5A 6B RJ45 2 7A 8B Fundamental structure of RC3000...
Page 37: ...audio relay card explanation RC3000 SUB DM2 is a 2W audio relay card with E M signal used for transmission of signal and voice between offices There totally 8 channels decided by hardware unchangeable...
Page 38: ...5 1 1TA 2TB 3RA 4RB 6E 7M RJ45 2 1TA 2TB 3RA 4RB 6E 7M RJ45 3 1TA 2TB 3RA 4RB 6E 7M RJ45 4 1TA 2TB 3RA 4RB 6E 7M Note 1TA and 2TB is 2 wire voice Tx 3RA and 4RB is 2 wire voice Rx 6E is E signal Rx an...
Page 39: ...first user E1 to it If V35 data is put into the third slot and 17 30 channels of the first user E1 are idle system will distribute 17 30 channels of the first user E1 to it or 17 31 in PCM31 frame mod...
Page 40: ...st slot is 0 31 0 indicates that shutdown the transmission of this user card and the startup channel is channel 1 If other slots have already occupied the channels of main cross group there will alarm...
Page 41: ...Timing B TCK B O 23 Terminal Timing A SCTE A I 24 Terminal Timing B SCTE B I 16 Request to Send RTS I 4 Clear to Send CTS O 5 Data Set Ready DSR O 6 Data Carrier Detect DCD O 8 Data Terminal Ready DTR...
Page 42: ...g data FDX ON full dulplex Ethernet interface standard compliant 7 8 3 Ethernet data card configuration explanation Ethernet user card has many functions and both Hyper Terminal and network management...
Page 43: ...ation RC3000 SUB D422 user card has standard serial data interface There are 8 channels whitch is decided by hardware unchangeable Four RC45 connectors make up of the 8 channels and each RJ45 connecto...
Page 44: ...follows Channel 1 2 3 4 Pins RJ45 1 1A 2B RJ45 1 3A 4B RJ45 1 5A 6B RJ45 1 7A 8B Channel 5 6 7 8 Pins RJ45 2 1A 2B RJ45 2 3A 4B RJ45 2 5A 6B RJ45 2 7A 8B Fundamental structure of RC3000 SUB DMT 1 2 3...
Page 45: ...J45 1 1A 2B RJ45 1 3A 4B RJ45 1 5A 6B RJ45 1 7A 8B Channel 5 6 7 8 Pins RJ45 2 1A 2B RJ45 2 3A 4B RJ45 2 5A 6B RJ45 2 7A 8B Fundamental structure of RC3000 SUB DSR 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Figu...
Page 46: ...t port rate is 10M auto negotiation disable F Ethernet port works in full duplex mode auto negotiation disable SW1 8 Full half duplex N Ethernet port works in half duplex mode auto negotiation disable...
Page 47: ...Relative E1 line is doing the loop back test F Local loop back 5 Loop back type N Remote loop back SW2 6 8 Reserved Reserved FFFN Impedance of 3rd E1 is 120 1 4 3rd E1 impedance NNNF Impedance of 3rd...
Page 48: ...for necessary line tests e For the devices to be installed please consider their positions and the length of cables We recommend you have a whole topology first 8 3 Installation 8 3 1 Device fixing RC...
Page 49: ...u need network management cascade connect cable to LINK DOWN interface Please connect to network management interface before device powered on if you are not sure of common grounding 8 3 3 Powered on...
Page 50: ...face has been correctly connected b Device connected to RC3000 works normally c If E1 is not used please shut it down d Verify the impedance of both ends match each other or change the impedance e Ver...
Page 51: ...trace clock each other this phenomenon will happen Please check the clock configuration If these are not the reasons please contact us for technical support 9 6 Not all devices in a network can be ne...
Page 52: ...a normally Otherwise check other configuration f Check serial interface If these are not the reasons why you cannot configure the device please contact us for technical support 9 8 Memory information...
Page 53: ...nterface RJ45 of RC3000 with PC serial interface DB9 before connecting make sure that both RC3000 and PC have grounding protection and you should connect the cable to CONSOLE interface of RC3000 first...
Page 54: ...prompt is Please input password and click Enter Password When enter the password there will be a for every input character If you want to change the password use BackSpace key for wrong enters passwo...
Page 55: ...and system will not deal with invalid commands 10 4 Device set query In main menu press number key 1 and then there will be device set query menu 1 Device ID and Baud rate 2 Line Board info RAM 3 Lin...
Page 56: ...are Version REV A 0 Optical Modul Type S1 Alarm Mask 1 Mask Optical LOS Frame LOF E 3 ERROR E 6 ERROR Local 0 0 0 0 Remote 0 0 0 0 Loopback State No Loopback Ether Net Set Ether Net E Port Open Link S...
Page 57: ...ion saved in EEPROM 10 4 5 Clock CRC and Net information Indevice set query menu press number key 5 and there will be E1 using and mode information Real information Clock Mode Recovered Clock 1 E1 Aut...
Page 58: ...k 0 0 0 0 0 0 0 4th E1 1 Mask 0 0 0 0 0 0 0 Device Query Command 1 8 Menu Display M Return Q Command There are two parts information one is the information saved in RAM and the other part is the infor...
Page 59: ...er board type 8 Ethernet data user card Type 8 Ether Net Board Channel Number 8 Set Mode Software Signal None Channel Main Channel Band Width Buffer 256Kbps Defeat Link Default Set Half Duplex Link St...
Page 60: ...o 1 4 Esc Cancel 1 Enter group number 1 cross connection of the first E1 will be displayed First E1 Cross Set Channel 1 2 3 4 5 6 7 8 cross 0 0 0 5 2 5 3 5 4 5 5 5 6 5 7 5 8 8 0 0 0 0 0 0 0 0 0 0 0 0...
Page 61: ...31 0 0 indicates there is no cross connection Address indication result of row number plus column number is the channel number For example 1 18 the address is 16 2 18 that is to say the data in this c...
Page 62: ...1 18 1 19 1 20 1 21 1 22 1 23 1 24 24 0 0 0 0 0 0 0 0 0 0 0 0 0 0 CROSS Query Command 1 4 Menu Display M Return Q Command Note in this table the address indicates the output data direction and the co...
Page 63: ...mation query menu press number key 2 there will be the following information Input Group No 1 4 Esc Cancel 1 Enter group number 1 there will transmit signal status information First Group Transmit Sta...
Page 64: ...ystem Alarm EEPROM Block Main Correct T T T E1 Block Correct T T T 2M Block Correct T T T Version Correct T T T User Board Com 1 Success 3 Success Line Board Com Fail Temp Sensor Normal 30 Fans Normal...
Page 65: ...a new Baud rate If you do not input number but press ENTER key the old Rate will still be effective And if you input a number and then press ENTER key this configuration will be effective The range of...
Page 66: ...3000 will set a steady clock mode according to E1 using status and board information When there are alarms system will judge whether to change the clock mode if necessary RC3000 will find a valid cloc...
Page 67: ...ouble E1 direction Device 3 Set all DIP switches OFF use one E1 time slot 0 and single E1 direction If connect two RC3000 devices through two E1 the number of used E1 will not be same as that of netwo...
Page 68: ...t RS232 serial interface of PC with LINK UP interface of device 1 device 1 and device 2 device 2 and device 3 device 3 and device 4 device 4 and device 5 are connected through E1 cable and connect LIN...
Page 69: ...3 Esc Cancel If the relative user board does not exist there will be the following information The First board is not exist System Set Command 1 9 Menu Display M Return Q Command If the user board ex...
Page 70: ...Command Note the command explanation is available in 8 14 RS232 and RS422 user board set menu 10 9 9 DCD and RTS of V35V24 Board with Alarm Set In System Set menu press number key 9 to configure the...
Page 71: ...ress E key to finish configuration and ESC to cancel configuration The configuration items are Loopback Direction 1E1 Loopback 2E1 Loopback 3E1 Loopback 4E1 Loopback 10 10 3 ALS Set In optical line bo...
Page 72: ...bandwidth value in the second row and just press ENTER the old configuration will be reserved If you set the bandwidth value the entering can only be number and within the range of 0 4095 and press EN...
Page 73: ...rmat PCM30 or PCM31 use to change configuration items Press ENTER to confirm configuration press E key to finish configuration and ESC to cancel configuration Configuration items are First E1 Mode Sec...
Page 74: ...r board RC3000 SUB DSO E M2 audio relay card RC3000 SUB DM2 E M4 audio reley card RC3000 SUB DM4 and magneto telephone card RC3000 SUB DMT 10 12 1 Input Signal In user board set menu press number key...
Page 75: ...the occupied channel number the entering can only be number and within the range of 0 31 and press ENTER the new configuration will be effective BackSpace key is available to modify RC3000 SUB DV35 i...
Page 76: ...er board set menu press number key 2 to configure Rx data phase Receive Data Phase Positive In this status use key to change the configured value Positive or Negative Press ENTER to confirm configurat...
Page 77: ...r code test V35 user board will transmit error code periodically and its Rx will test the Rx data If the Rx error code is same with that of Tx error code test indicator light PAT_OK will ON otherwise...
Page 78: ...st press ENTER the old configuration will be reserved If you set the occupied channel number the entering must within the range of 0 31 and press ENTER the new configuration will be effective BackSpac...
Page 79: ...his command will reset ether net port Run this command Y N In this status press Y to reset the board and press N to cancel the operation Other enterings are invalid 10 15 RS232 and RS422 user board se...
Page 80: ...e next item configuration Time Slot Start No for Time Slot Out The entering must be a number from 1 to 31 press ENTER to confirm and start the configuration of next item The system will check the ente...
Page 81: ...y 3 to delete group cross Group No for Delete Cross The entering must be a number from 1 to 8 press ENTER to confirm and start the configuration of next item The system will check the entered number i...
Page 82: ...7 Clear Reset and Board Change Flag 8 Test Watchdog 9 Test EEPROM Operate Command 1 9 Menu Display M Return Q Command 10 17 1 System Reset In operate menu press number key 1 to reset the system Run t...
Page 83: ...tory All saving data will be losed The device will restart Run this command Y N All information in EEPROM will be invalid if you press Y key and press N key will exist By default except hardware versi...
Page 84: ...main menu press number key 8 there will be console set menu 1 Language Select 2 Password Set Console Set Command 1 2 Menu Display M Return Q Command 10 19 1 Language Select In console set menu press...
Page 85: ...on will be successful otherwise there will be the prompt Twice new password is not same password setting failed Anytime press ESC to cancel and the control characters are invalid 10 20 Quit In main me...
Page 86: ...Raisecom Technology Co Ltd 85 2005 Raisecom Technology Co Ltd All trademarks are the property of their respective owners Technical information may be subject to change without prior notification...