General Specifications

Auto-off:

 turns meter off after approx. 50 minutes

to extend battery life.

Indicators:

 Continuity beeper (<100

W

). Low

battery. Overrange: "OL"  is displayed.

Environmental: 

Operating temperature 32°F to

122°F, storage 0°F to 140°F with batteries

removed, RH<70%.

Measurement rate:

 2.5 times/sec nominal.

Battery life:

 >200 hours typical with carbon zinc.

Battery type: 

9V NEDA 1604 type

Functional Specifications

Accuracy specifications @ 74°F±8°F, relative

humidity less than 70%. Accuracy specified as

±% of reading ± number of least significant

digits.

DC Voltage

Ranges: 

200mV, 2000mV, 20V, 200V, 600V.

Resolution:

  100µV

Accuracy: 

±(0.5%rdg  +  1dgts)

Input  impedence:

  10M

W

AC Voltage (50Hz-500Hz)

Ranges:

 200mV, 2000mV, 200V, 600V.

Resolution:

  100µV

Accuracy: 

200mv, 200mV range ±(1.2% + 4)

                  200V, 600V range ±(2% rdg + 4dgts)

Input  impedence:

  10M

W

Limited Warranty

This meter is warranted against defects in

material or workmanship for one year from

date of purchase. Fieldpiece will replace or

repair the defective unit, at its option, subject

to verification of the defect.

This warranty does not apply to defects

resulting from abuse, neglect, accident,

unauthorized repair, alteration, or

unreasonable use of the instrument.

ANY IMPLIED WARRANTIES ARISING

OUT OF THE SALE OF A FIELDPIECE

INSTRUMENT’S PRODUCT, INCLUDING

BUT NOT LIMITED TO IMPLIED

WARRANTIES OF MERCHANTABILITY

AND FITNESS FOR A PARTICULAR

PURPOSE, ARE LIMITED TO THE ABOVE.

FIELDPIECE SHALL NOT BE LIABLE FOR

LOSS OF USE OF THE INSTRUMENT OR

OTHER INCIDENTAL OR

CONSEQUENTIAL DAMAGES, EXPENSES,

OR ECONOMIC LOSS, OR FOR ANY

CLAIM FOR SUCH DAMAGE, EXPENSES,

OR ECONOMIC LOSS.

State laws vary. The above limitations or

exclusions may not apply to you. This

warranty gives you specific legal rights, and

you may also have other rights which vary

from state to state.

General Description

The LT17 measures temperature

(ambient air as well as pipes), capacitance

(motor start and motor run capacitors),

microamps (flame rectifier diode circuit), and

frequency (variable frequency motor

controls). In addition it measures volts

(AC&DC), resistance and has a continuity

beeper and diode check. The LT17 works

with all Fieldpiece accessories, when

connected with our deluxe test leads (ADL2).

For Your Safety...

Inspect the test leads for damage to the

insulation or exposed metal. Replace if

suspect. Never ground yourself when taking

electrical measurements. Do not touch

exposed metal pipes, outlets, fixtures, etc.,

which might  be at ground potential. Keep

your body isolated from ground by using dry

clothing, rubber shoes, rubber mats, or any

approved insulating material. When

disconnecting from a circuit, disconnect the

"RED" lead first, then the common lead.

Work with others. Use one hand for testing.

Turn off power to the circuit under test before

cutting, unsoldering, or breaking the circuit.

Keep your fingers behind the finger guards

on  the probes.

All voltage ranges will withstand up to

600VDC or 600VAC. Do not exceed 600VAC/

DC.

Disconnect the meter from the circuit

before turning any inductor off, including

motors, transformers, and solenoids. High

voltage transients can damage the meter

beyond repair. Do not use during electrical

storms.

Capacitance

Ranges:

 200

m

F, 2K

m

F, 20K

m

F

Accuracy: 

±(4% rdg + 10 dgts)

Test  Voltage: 

<3.5V

Test  Frequency:

  21Hz

AC Current

Ranges:

  200µA,  20mA

Resolution:

  100nA

Accuracy:

 ±(1.5% rdg + 1dgts)

Voltage  burden:

  250mV  for  200µA  range.

400mV for 20mA range.

DC Current:

Ranges:

  200µA,  20mA

Resolution:

  100nA

Accuracy:

   ±(1.0% rdg + 1 dgts)

Voltage  burden:

  250mV  for  200µA  range.

400mV for 20mA range.

Resistance (Ohms)

Ranges:

 200

W

, 200K

W

, 20M

W

Resolution:

  0.1

W

Accuracy: 

200

W

, 200K

W

 ranges

±(1.0% rdg + 4 dgts)

20M

W

 range ±(2.0% rdg + 4 dgts)

Open circuit voltage: 

0.3V (3V on 200

W

 )

Continuity

Audible indication:

 less than 100

W

Response time:

 100ms

Frequency (auto ranging)

Range:

 10Hz to 40KHz

Sensitivity:

 3.5VRMS min.

Accuracy: 

±(0.1% rdg + 3 dgts)

Diode test

Resolution: 

1mV

Accuracy: 

±(1.5% rdg + 1 dgt)

Test current: 

1.0mA ± 0.6mA

Open circuit voltage:

 3.0V typical

Overload Protection

V

AC

 + V

DC

200mV range

500VDC / 350VAC

for 15 sec

>200mV range

600VDC / 600VAC

A

AC

 + A

DC

0.5A / 500V

mA input

(6.35mmx32mm)

m

A input

model RFM74

Capacitance

0.1A / 250V

(5mmx20mm)

model RF16

Ohms (

W

)

500VDC / 500VAC

Diode

500VDC / 500VAC

Continuity

500VDC / 500VAC

Temperature

30 VAC, 60 VDC

Battery Replacement

The multimeter displays “ 

 ” to indicate

that the battery needs a replacement to

maintain proper operation.

Temperature (K-type T/C)

Range:

 -30°F to 1000°F 

 Resolution

: 0.1°F

Accuracy: 

±(1°F), 32°F to 120°F;

±(1%+1.5°F), -4°F to 750°F; ±(2%+3°F),

-30°F to -4°F & 750°F to 1000°F. ±(1°C),

0°C to 120°C; ±(1%+1°C),

0°F to 400°F; ±(2%+3°C), -

35°C to -0°C & 400°C to

600°C.

Ice bucket calibration

 For accuracies of ± 1°F

(32°F to 120°F) calibrate the

LT17 to a known temperature.

A glass of stabilized ice water is

very close to 32°F and is

usually  very  convenient.

1. Remove back of the meter. Hold the

battery in place with a rubber band.

2. Stabilize a large cup of ice water.

3. Select the °F range on the LT17.

4. Immerse the probe and let it stabilize.

5. Adjust VR2 until the read out is within 2°F

of the specified 32°F. Then adjust VR3

until the meter reads within 0.1°F of 32°F.

Display 

o

C or 

o

F

1. Locate the pins above/right of VR3.

2. Short (jumper) pins to display 

o

C.

DO NOT APPLY VOLTAGE TO THE

CAPACITANCE JACK OR THE

CURRENT JACK. Even low voltages

can cause a current overload and blow

a fuse. Replace blown fuse to regain

function.

Disconnect the thermocouple when

measuring voltage.

DISCONNECT TEST LEADS WHEN

MEASURING TEMPERATURE.

!

WARNINGS

VR2

VR3

VR1

Reviews: