Operating Instructions

Model MM45

Digital Multimeter

SAFETY INFORMATION

The following safety information must be observed
to ensure maximum personal safety during the
operation of this meter:
Do not use the meter if the meter or test leads look
damaged, or if you suspect that the meter is not
operating properly.
Never ground yourself when taking electrical
measurements. Do not touch exposed metal pipes,
outlets, fixtures, etc, which might be at ground
potential. Keep your body isolated from ground by
using dry clothing, rubber shoes, rubber mats, or
any insulating material. 
Turn off power to the circuit under test before
cutting, unsoldering, or breaking the circuit. Small
amounts of current could be dangerous. 
Use caution when working above 60V DC or 30V AC
rms. Such voltages pose a shock hazard.
When using the probes, keep your fingers behind
the finger guards on the probes. 

MM45 REV3 7/05

NOTE

This instrument is only to be used by a suitably
trained and competent person.

The symbols used on this instrument are:

Measuring voltage which exceeds the limits of the
multimeter may damage the meter and expose the
operator to a shock hazard. Always recognise the
meter voltage limits as stated on the front of the
meter.  

SPECIFICATIONS
Display: 
3½   digit liquid crystal display (LCD) with a 
maximum reading of 3200.  
Analog bar graph: 34 segments with measurements
12 times per second.
Polarity: Automatic,(-) negative polarity indication. 
Overrange: “OL” mark indication.
Zero: automatic.
Low Battery Indication: The 

is displayed when

the battery voltage drops below the operating level.  
Measurement rate: 2 times per second, nominal.
Operating environment: 0°C to 50°C at < 70% R.H.
Storage temperature: -20°C to 60°C, 0 to 80% R.H.
with battery removed from meter.  
Battery life: 200 hours typical with carbon-zinc.
Battery: Single standard 9-volt battery, MN1604,
NEDA 1604, JIS 006P, IEC 6F22, PP3.
Dimensions: 147mm (H)x 70mm (W)x 39mm (D).
Weight: Approx. 345g (11.8 oz) including holster.
Auto power off: Meter automatically shuts down after
approx. 10 minutes of inactivity.
Accessories: One pair test lead, One spare fuse, 9V 
battery (installed) and Operating Instructions. 

Range

320mV

3.2V

32V

320V

600V

Range

320µA

3200µA

32mA

320mA

10A

Range

320

Ω

3.2k

Ω

32k

Ω

320k

Ω

3.2M

Ω

32M

Ω

0-2000

Range

320

Ω

Voltage

(50/60Hz)

Current

(50/60Hz)

OHM

Diode

Test

Continuity

Check

AC Accuracy

N / A

± 2.0% rdg+4d

AC Accuracy

± 2.5% rdg+4d

± 3.5% rdg+4d

Accuracy

± 2.0% rdg+3d

± 1.5% rdg+3d

± 2.5% rdg+3d
± 5.0% rdg+5d

± 10% rdg+2d

Audible Indication

< approx. 20

Ω

Input Impedance

> 1000M

Ω

11M

Ω

10M

Ω

Voltage Burden

0.2V

2V

0.2V

2V

2V

Test Current

< 0.7mA

< 0.13mA

< 13µA

< 1.3µA

< 0.13µA

0.5mA (Vf = 0.6V)

Test Current

< 0.7mA

DC Accuracy

± 1.2% rdg+1d
± 0.8% rdg+1d

± 1.2% rdg+1d

DC Accuracy

± 2.0% rdg+1d

± 3.0% rdg+3d

Resolution

100m

Ω

1

Ω

10

Ω

100

Ω

1k

Ω

10k

Ω

1mV

Resolution

100m

Ω

Caution, risk of electric shock

Caution, refer to accompanying
documents

Equipment protected throughout
by Double Insulation (Class II)

Alternating current

Direct current

Ground

z

Maximum Input

600VDC or

600VAC rms

Input Protection

0.5A/250V fuse

10A/250V fuse

Input Protection

500VDC or

500VAC rms

500V DC or AC rms

Input Protection

500V DC or AC rms

~

HIGH ENERGY SYSTEMS

GS38 advises fused test leads to be used when 

working on high energy systems. Suitable leads

are Martindale TL55.

The instrument meets the requirements for double
insulation to BS EN 61010-1 at 600V Installation
Category

III

Installation Category

III

(distribution

level) relates to transient overvoltage likely to be
found in fixed installation wiring.