background image

23

Summary of Contents for 23

Page 1: ...23 ...

Page 2: ...23 ...

Page 3: ...Red Black Red Black fig 1 DC AC Voltage Measurement Red Black fig 2 Measuring Resistance fig 3 DC Current Measurement fig 4 Replacing the Battery 1 Illustrations ...

Page 4: ...rotection 600V DC AC B AC Voltage Range 6 600V 66 00V 600 0V Resolution 1mV 10mV 100mV Accuracy 1 2 5 Overload protection 600V DC AC C Resistance Range 660 0Ω 6 600kΩ 66 00kΩ 660 0kΩ 6 600MΩ 66 00MΩ Resolution 0 1Ω 1Ω 10Ω 100Ω 1kΩ 10kΩ Accuracy 1 2 2 1 2 1 2 2 1 5 2 Overload protection 250VAC 2 ...

Page 5: ...n 1mV Accuracy 0 5V 0 8V Open circuit voltage approx 3 0V Overload protection 250VAC E Continuity Test Range Resolution 0 1 Accuracy Around 30Ω the buzzer beeps Open circuit voltage approx 1 2V Overload protection 250VAC 3 Tables ...

Page 6: ...z 0 001kHz 0 01kHz 0 1kHz 0 001MHz 0 01MHz Accuracy 0 1 3 Overload protection 250VAC G Duty Cycle Range 0 1 99 9 Resolution 0 1 Accuracy For reference only Overload protection 250VAC H DC Current Range 66 00A 1000A Resolution 0 01A 1A Accuracy 1 5 40 1 5 8 Overload protection 1000A DC AC 4 ...

Page 7: ...I AC Current Range 66 00A 1000A Resolution 0 01A 1A Accuracy 2 40 2 8 Overload protection 1000A DC AC Frequency Response 50Hz 60Hz 5 Tables ...

Page 8: ...enska 16 23 Norsk 24 31 Dansk 32 39 Suomi 40 47 Deutsch 48 58 Nederlands 59 67 Français 68 76 Italiano 77 86 Español 87 95 Português 96 104 Ελληvikά 105 114 Polski 115 125 Eesti 126 134 LietuviŠkai 135 144 Latviski 145 154 Pycckий 155 165 6 English ...

Page 9: ...Contents Overview General specification Safety information Voltage DC and AC Current DC Current AC Resistance Frequence and Duty cycle Diodes test Continuity test Battery 7 English ...

Page 10: ...ition witch makes this instrument easy to handle for the user For indoor use General Specifications Measuring range and accuracy see page 2 5 Auto range Display shows selected function Maximum Display 6666 or 3 5 6 digits True RMS for Voltage AC Surge current Current AC Displays shows OL when the instrument is overloaded Max conductor diameter for clamp 45 mm Display backlight Automatic off after1...

Page 11: ...ds IEC61010 in pollution degree 2 category CAT II 600V CAT III 300V over voltage and double insulation Warning To avoid possible electric shock or personal injury and to avoid possible damage to the Meter or to the equipment under test adhere to the following rules Before using the Meter inspect the case Do not use the Meter if it is damaged or the case or part of the case is removed Look for crac...

Page 12: ...00 V When the Meter working at an effective voltage over 60V in DC or 42V rms in AC special care should be taken for there is danger of electric shock Do not use or store the Meter in an environment of high temperature humidity explosive inflammable and strong magnetic fields The performance of the Meter may deteriorate after dampened When using the test leads keep your fingers behind the finger g...

Page 13: ...hold function H shows on display when value is frozen θHz Change between Hz and duty cycle when the meter is at Hz V or A position ZERO Zeroing the display before measuring DC current Voltage measurement DC and AC See fig 1 1 Insert red test lead into the VΩHz terminal and black test lead into the COM terminal 2 Set the rotary switch to V position 3 Select DC or AC with select button Display shows...

Page 14: ...n to zeroing When the meter is at 1000 A range it displays 0 and it is not allowed to press zero button Current measurement AC See fig 3 1 Set the rotary switch to 66 A or 1000 A Display shows AC Start with 1000 A when the value is unknown 2 Open the jaws and center one of the conductor Make sure the conductor is placed at center of the jaw Only one conductor at each time can be measured The measu...

Page 15: ...4 Connect the test leads across with the object being measured The measured value shows on the display Note The test leads can add 0 1Ω to 0 3Ω of error to resistance measurement To obtain precision readings in low resistance measurement that is the range of 200Ω short circuit the input terminals beforehand and record the reading obtained This is the additional resistance from the test lead OL dis...

Page 16: ...st sends a current through the semiconductor junction and then measures the voltage drop across the junction A good silicon junction drops between 0 5V and 0 8V To test a diode out of a circuit connect as follows 1 Insert red test lead into the VΩHz terminal and black test lead into the COM terminal 2 Set the rotary switch to diode position 3 Push select button to select diode function Displays sh...

Page 17: ...across with the object being measured The buzzer sounds if the resistance of a circuit under test is between 30Ω and 100Ω Replacing the Battery See figure 4 Replace battery as soon battery symbol is shown on display 1 Disconnect the connection between the testing leads and the circuit under test when battery indicator appears on the display 2 Turn the Meter to OFF position 3 Remove the screw and s...

Reviews: