background image

Please Read before using this equipment.

Digital Multimeter With Voice Readout

2218202

User’s Manual

Summary of Contents for 2218202

Page 1: ...Please Read before using this equipment Digital Multimeter With Voice Readout 2218202 User s Manual ...

Page 2: ...h electrical circuits and testing procedures Not for commercial or industrial use If this equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired To reduce the risk of fire or shock hazard do not expose this product to rain or moisture A Word About Safety We have taken every precaution in designing this meter to ensure that it is as sa...

Page 3: ...ACV OHM DIODE CONTINUE CAP HZ DC AC mA Keys Hold key A short press will fix the display on the current value and hold it A second short press returns multimeter to normal mode The key is operative in all ranges Function key To select the function for the meter press the function key This key is operative in DC V AC V OHM DIODE BEEP and DC AC mA functions Rel key Relative measurement This key is ope...

Page 4: ...er try to measure a DC voltage above 1000 volts or an AC voltage above 750 volts RMS Over Voltage Protection 1000V DC 750V AC Operating Temperature 32 to 109 F 0 to 43 C Storage Temperature 4 to 140 F 20 to 60 C Relative Humidity 80 maximum Power Source 3 AA batteries Power Consumption 112 5 mW Typical Dimensions HWD 6 14 x 3 15 x 1 4 156 X 80 X 35 mm DC Volts Range Max Reading Resolution Accuracy...

Page 5: ...unts 5 120 uF 5 119 uF 1 nF 1 0 FS 10 Counts 512 0 nF 511 9 nF 100 pF 1 0 FS 10 Counts 51 20 nF 51 19 nF 10 pF 1 0 FS 10 Counts Frequency Note Normal Sensitivity 50 mV rms 10 MHz sensitivity 1 0 V rms Range Max Reading Accuracy 10 00 MHz 10 00 MHz 1 0 2 Counts 5 000 MHz 5 000 MHz 1 0 2 Counts 500 0 KHz 500 0 KHz 1 0 2 Counts 50 00 KHz 50 00 KHz 1 0 2 Counts 5 000 KHz 5 000 KHz 1 0 2 Counts 500 0 H...

Page 6: ... meter s case by pulling the tabs on the case in opposite directions Then unwind the test leads from inside the cover Caution The test leads are permanently attached to the meter Do not try to remove them Rotate the selector to the function you want to use Then connect the test leads to the circuit you want to measure See the unit of measure on the front of the meter to distinguish the range For e...

Page 7: ...he voltage developed across an unknown resistance Warning Be sure the circuit under testing has all power removed and any associated capacitors are fully discharged before you make a resistance measurement 1 Set the selector to OHM DIODE CONTINUE Caution Your meter has a circuit to protect the resistance range from over voltage However to prevent accidentally exceeding the protection circuit s rat...

Page 8: ...er to announce the test result press the switch on the red test lead for less than 1 5 seconds If you want the meter to be alluminated press the switch on the red test lead for more than 1 5 seconds and the meter will be lit for 30 seconds Frequency Measurement Position the selector switch on the Hz function Automatic range selection Read the measured value Hold if necessary by pressing the HOLD k...

Page 9: ... included with your Product or other accessories or external electrical systems resulting from the use of your Product Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you Defacing the serial number or using your Product for commercial or institutional purposes voids this warranty Are There Other Warra...