1/118 

 

INSTRUCTION MANUAL 

GRAPHIC MULTI-METER 
MODEL G1000 Series 

( Strain Gauge / Process Input ) 

 
 
 
 
 
 

 

 

Summary of Contents for G1000 Series

Page 1: ...1 118 INSTRUCTION MANUAL GRAPHIC MULTI METER MODEL G1000 Series Strain Gauge Process Input...

Page 2: ...alog output RS 232C Output unit 0 Strain gauge Process input unit Input unit Series name Standard equipment of the comparison output Open collector output is carried out Display model 2 Japanese Engli...

Page 3: ...Example 21 5 2 Waveform Comparison Waveform Displacement Comparison Example 22 5 3 Set Value Input Screen 23 5 4 Data Setting Tree 24 5 5 Data Setting List 25 6 Basic Function Setting Setup 30 7 Stra...

Page 4: ...Ach 88 19 2 Analog Input Setting Bch 89 19 3 Calibration Ach Actual Load Calibration 90 19 4 Calibration Ach Equivalent Calibration 91 19 5 Comparison Setting Value Setting Ach Bch Comparator 93 19 6...

Page 5: ...d value and graph can be displayed Various hold functions can be performed for each of Ach and Bch individually The peak value valley value peak valley value maximal value minimal value inflection poi...

Page 6: ...son and output the result For hold type setting in hold function comparison set values graph display setting it can be saved up to 16 patterns and can be switched by pattern select signal or RS easily...

Page 7: ...7 118 2 Outside Dimensions and Mounting Method 1 Outside dimensions Front Side Rear Panel cutting hole When you have no memory card function there is no SD cover of the front upper part...

Page 8: ...ness is 1 to 5mm Use tightening torque of about 0 39 N m 2 Do not locate the Meter in a place where ambient temperature is outside the range of 0 to 40 humidity is outside the range of 35 to 85 and hu...

Page 9: ...r of the front upper part 3 1 Connection of Power Supply AC input voltage is 100 to 240V AC 10 50 60Hz DC input voltage is 24V DC 15 Connect power supply to terminals No 1 and terminal No 2 N Terminal...

Page 10: ...t power supply voltage Sensor power to the sensor and turn off power to this Meter please refer to 7 1 4 Sensor power Terminals 4 to 7 are for input of Ach Connect the shield shielding wire of the sen...

Page 11: ...BUSY output is used when SD memory card function is available Specified connector When a connectors other than specified is used the Meter cannot be used Type with solder E25 403N 150 with case made b...

Page 12: ...COM Common terminal The common output terminal of terminal No 1 to 7 OUT1 to 5 Error SYNC For details refer to 3 4 4 Each output equivalent circuits Terminal No 9 Start Peak hold Ach STA Input termina...

Page 13: ...t and BCD output For details refer to 3 4 5 Pattern select and 6 Each input equivalent circuits Terminal No 22 Graphic start START Input terminal Start the reading of analog input waveform indicated v...

Page 14: ...pprox 5V Bch Current input 0 to 20mA 4 to 20mA Approx 5V Inside of meter Terminal No 14 AOUTA Load resistance More than 10K I O control connector Terminal No 15 AOUTB Terminal No 16 AG External equipm...

Page 15: ...vel Terminal Pattern P3 P2 P1 P0 Caution When performing the Waveform Comparison or Waveform Displacement Comparison P00 to P07 can be used Don t use P3 P00 1 1 1 1 P01 1 1 1 0 P02 1 1 0 1 P03 1 1 0 0...

Page 16: ...cated value and bar graph Comparison output monitors HH LL Red HI LO Yellow GO Green None White No monitor 4 2 Multi Display Screen 2 channel HI LO comparison output monitor Ach DZ digital zero key Ac...

Page 17: ...TART STOP key X axis scale and time s 4 4 Waveform Comparison Display Screen Ach Bch Y axis indicated value and unit Y axis scale unit X axis scale and time s HI limit waveform set value LO limit wave...

Page 18: ...of display change key are available The state when each of be pressed is shown according to each meter setting The display screen changes as follows when Ach and Bch are selected by meter setting A c...

Page 19: ...Setting of unit is performed at 7 1 3 Analog Input Setting Ach Bch 8 Display of Bar graph Can be displayed for each of Ach and Bch individually High limit of bar graph for Ach is SPAN indicated value...

Page 20: ...arison Waveform Displacement Comparison screen Unit setting is performed by 7 1 3 Analog Input Setting Ach Bch 15 Display indicated value of X axis Display the displacement indicated value and unit of...

Page 21: ...rdinary Display Screens Caution Screen for Starting Setting Main Setting Screen Note When no memory card function SD setup button is not displayed Itemized Setting Screen 10 key Input Screen Set value...

Page 22: ...Screen Note When no memory card function SD setup button is not displayed Itemized Setting Screen Set value Input Screen Each Set key HI LO limit waveform set value Comparison range setting Correctio...

Page 23: ...s set value Displays set value INPUT KEY Used to set data to be set with indicator Data name to be set Enter set value with 10 key pad Acquire set value and finalize with SET key Set value becomes blu...

Page 24: ...System BCD Output Output Analog Output Output Hold Function Hold Waveform Comparison Waveform Displacement Comparison Waveform When an output unit is equipped with can set output analog or BCD settin...

Page 25: ...0 0 to 99 min Contrast 0 to 255 Cross Talk 33 0 to 63 Digital ZERO Backup OFF OFF ON Language Japanese Japanese English BPS 9600 38400 19200 9600 4800 2400 BPS Data Length 7 7 8 Parity Even Even Odd N...

Page 26: ...ing Average off off 2 4 8 16 32 64 128 256 512 1024 times Analog Filter 600 10 30 300 600 Hz Digital Limiter HI 99999 99998 to 99999 Digital Limiter LO 99999 99999 to 99998 Step 1 1 2 5 10 Comparison...

Page 27: ...lect P00 to 15 Pattern Copy P00 to 15 Hold Normal 1 Normal 2 Sample 3 Peak 4 Valley 5 Peak valley 6 Area Peak 7 Area Valley 8 Area Peak Valley 9 Time Peak 10 Time Valley 11 Time Peak Valley 12 Level T...

Page 28: ...ec Start Type Ext signal 1 Free Run 2 Ext Signal 3 Wave Start Level 4 E S W S Wave Data Read Rejection Data Read 1 1 Times Before 2 2 Times Before 3 3 Times Before 4 4 Times Before 5 Rejection Data St...

Page 29: ...el A channel B channel Setting item Default value Setting range Protect Dz Off On Off Protect Strain Gauge Off On Off Ach Bch Protect Others Off On Off 1 Comparator 2 Hold 3 Linearization 4 Waveform 5...

Page 30: ...his state continues beyond the time setting the Meter considers this state to be stable Then moving average internally starts automatically When the value measured after the moving average and the pre...

Page 31: ...N 0 hold key OFF 1 ON 0 Internal operation OFF 1 ON 0 Input on delay Use Input on delay for the above mentioned control terminal and HOLD key STA Ach STB Bch control terminals can be used separately f...

Page 32: ...ning on power Comparison output OUT1 to OUT5 OFF BCD output open collector output OFF Analog output voltage output 0V current output 0mA Power on delay 0 no power on delay functions 9 Back Light Time...

Page 33: ...and English Itemized setting screen 6 6 14 Communication and Related Items The following setting can be performed on the set value select screen BPS 2400 4800 9600 19200 38400 Data Length 7 8 Parity...

Page 34: ...e doing calibration Itemized setting screen 1 5 Itemized setting screen 2 5 Itemized setting screen 3 5 1 Setting Channel Select Ach When Bch is selected 7 3 Analog Input Bch is performed 2 Pattern Se...

Page 35: ...IN value for the strain gauge sensor is 0 1 to 3 0mV V The setting range of SPAN set value indicated value is 100 to 99999 Select a set value on the set value select screen and then set in on the 10 k...

Page 36: ...mentioned 6 and then press SPAN key for resetting If Error 5 still occurs it is necessary to press the key twice and to perform resetting from 5 Zero Calibration 7 Actual Load The measured value SPAN...

Page 37: ...or press and press Actual Load key on the above mentioned itemized setting screen for resetting If Error 5 still occurs it is necessary to press the key twice and to perform resetting from 5 Zero Cal...

Page 38: ...ion Setting 2 System screens to turn off protect 2 Check sensor power supply Check the contents of settings on the setting screen return to the ordinary display screen turn off power to the Meter and...

Page 39: ...value on the 10 key input screen Setting conditions Full Scale Offset Scale Setting range Full Scale Set the indicated value when a Full Scale Input value is entered Offset Set the indicated value wh...

Page 40: ...aling setting Full Scale Input 10 000V Full Scale indicated value 2000 Offset Scale input 2 000V Offset Scale indicated value 0 Example of scaling setting Full Scale Input 20 000mA Full Scale indicate...

Page 41: ...e number of times of moving average is increased the indicated value is stabilized However response becomes slow Set it on the set value select screen Setting items OFF 2 4 8 16 32 64 128 256 512 1024...

Page 42: ...e indicated value crossed the set value of Wave Start Level in or direction Rising Edge when the indicated value crossed the set value of Wave Start Level in direction Trailing Edge when the indicated...

Page 43: ...ng Clear the screen and start the acquisition of waveform and graphic drawing START key OFF ON START signal OFF ON STOP signal OFF ON Drawing period acquire2048 Interval time Hold display screen Drawi...

Page 44: ...display screen and wait for the next satisfaction of condition 4 E S W S When START key or START signal turns ON and the indicated value satisfies Wave Start Level Start Condition clear the screen and...

Page 45: ...5 4 Comparison set value Set the comparison set value to be used at A channel B channel and 2 channel Set it on the 10 key input screen For 2 channel use the HI Limit set value and LO Limit set value...

Page 46: ...set value HI Hysteresis LO hysteresis set value LO Hysteresis LL hysteresis set value LL Hysteresis 6 Comparison output type Type Set a Type of comparison output Type on t he set value select screen S...

Page 47: ...nel and 2 channel Indicated value HH set value HH Limit HI set value HI Limit LO set value LO Limit LL set value LL Limit 1 In case of Normal operation type Output HH OFF ON 2 In case of Area type 3 I...

Page 48: ...esis set value minus mode operation Comparison output ON indicated value each set value Comparison output OFF indicated value each set value each hysteresis set value In case of comparison output bein...

Page 49: ...tions HH set value HI set value LO set value LL set value HH Limit HI Limit LO Limit LL Limit Each set value should be set according to setting conditions Setting can t be performed if conditions are...

Page 50: ...o STA STB signal 11 1 Hold Function Setting Setting procedure MODE key Caution Screen for Starting Setting Main setting screen HOLD key Itemized setting screen 1 3 1 Pattern Select Set a pattern to be...

Page 51: ...splay In case of Waveform Displacement Comparison W D a Set the Waveform start level Start Level at 99999 and execute starting When the displacement indicated value of X axis becomes 0 or over 0 acqui...

Page 52: ...hen the indicated value contains much noise the maximal value and minimal value of noise may be sometimes detected Check the indicated value on the screen and set the proper minimal value Minimal Valu...

Page 53: ...elay time from STA STB signal turning OFF to releasing hold for the indicated value Td 1 0ms MAX 3 The delay time from STA STB signal turning ON to starting the timer of delay Td ms MAX 4 Input ON del...

Page 54: ...e Note While in detection hold synchronizing signal output turns ON and continue in Detection Hold area Note The comparison output changes with the change of analog input value Perform the comparison...

Page 55: ...Note While in detection hold synchronizing signal output turns ON and continue in Detection Hold area Note The comparison output changes with the change of analog input value Perform the comparison wi...

Page 56: ...line only in Detection Hold area Indicated value 0 While in detection hold synchronizing signal output turns ON and continue in Detection Hold area Note The comparison output changes with the change o...

Page 57: ...output OFF ON 1 Note Hold area 2 RESET OFF ON Output hold While in hold synchronizing signal output turns ON and continue in Hold area Note The comparison output changes with the change of analog inp...

Page 58: ...al output OFF ON 1 Note Hold area 2 RESET OFF ON Output hold Detection time internal OFF ON While in hold synchronizing signal output turns ON and continue in Hold area Note The comparison output chan...

Page 59: ...area Indicated value 3 Synchronizing signal output OFF ON 1 Note Hold area 2 RESET OFF ON Output hold Start Level While in hold synchronizing signal output turns ON and continue in Hold area Note The...

Page 60: ...e STA STB OFF ON HOLD key OFF ON Comparison output OFF ON Analog input value Detection area Indicated value 3 Synchronizing signal output OFF ON 1 Note Hold area 2 RESET OFF ON Start Level While in ho...

Page 61: ...to 7 Select a Pattern Select before changing the set value 2 Comparison waveform writing Pattern Write Set a pattern in which to write the comparison waveform on the set value select screen The HI LO...

Page 62: ...nd reduces the Waveform sampling Sampling to prepare a comparison waveform HI limit comparison waveform is first prepared and then LO limit comparison waveform is prepared Used to move the waveform up...

Page 63: ...point and press OK key to set it Pressing ESC key after completion of setting will reset the drawing starting point When the cursor is moved furthermore to determine the next drawing point and press O...

Page 64: ...tion of setting will reset the edit starting point Move the cursor determine an edit end point and press OK key Pressing ESC key after completion of setting will reset the edit ending Move the cursor...

Page 65: ...rmine the end point of the comparison area Determine the end point of the comparison area with OK key Pressing ESC key after completion of setting will reset the comparison area end point When the ran...

Page 66: ...ro In case of waveform start level Start Level be a value other than 99999 after START signal or STRAT key turning ON when the indicated value of Y axis satisfied Start Level Start Condition digital z...

Page 67: ...OFF ON 2 1 STOP signal OFF ON OFF ON Outlying HI output ON Analog input waveform HI Limit waveform set value LO Limit waveform set value Wave start level Start Level OFF ON START key Comparison area 3...

Page 68: ...limit Displacement Min Value then output the result The displacement indicated value is shown in display screen as it is however the displacement indicated value is held as peak value and performed co...

Page 69: ...range of the screen Set a magnification on the set value select screen Setting magnifications 1 1 1 2 1 5 1 10 1 20 1 50 1 100 1 200 1 500 1 1000 1 2000 11 kinds 5 X Start Point The setting range is...

Page 70: ...s set in accordance with the next paragraph Pressing START key or turning on the start signal starts drawing When one screen is finished the period drawing screen at the interval time is held Set it o...

Page 71: ...RS 232C or RS 485 All the memorized waveforms outside the range are cleared 1 1 Times Before 2 2 Times Before 3 3 Times Before 4 4 Times Before 5 Rejection Data Store Rejection Data Store key is usua...

Page 72: ...15 Select a Pattern Select before changing the set value 3 Pattern Copy Set the pattern of the copy destination on the set value select screen Setting range 0 to 15 4 Set Number Set the set number use...

Page 73: ...f bellow mentioned 4 Initialize turn disable and not available when pressing 3 Setting value protect Protect Others Switch ON OFF when press for about 3 seconds continuously Used for disable of the se...

Page 74: ...is the case that does not operate normally at next power on Action example Pressing 1 Initialize Strain Gauge key Caution Screen for Starting Executing Setting Value Screen 5 Self Check Display Displa...

Page 75: ...eck I O The signal on the screen changes from blue to yellow while each input signal is set to ON Pressing each output signal key turns ON OFF output signal alternately 8 Self Check Sensor The check r...

Page 76: ...line is disconnected When connection between the sensor and SIG terminal is disconnected the check result of SIG is displayed as Error In case of disconnection SENSOR cannot be checked but the check...

Page 77: ...tput unit is mounted Pressing 0 50 or 100 key outputs voltage or current from the terminal of the selected type Pressing key returns to Itemized setting screen 4 4 Pressing MENU key returns to the nor...

Page 78: ...RXD RTS CTS SG Non inverted Inverted Number of Connecting meters 1 31 meters Cable Length 15m 500m at max total 1 Communication setting BPS Data Length Parity Stop Bit Delimiter RS 485 ID Each settin...

Page 79: ...ch command 16 3 Command Format and Response Format In case of RS 485 1 Occupation and releasing of communication line 1 Line occupation ENQ 00 to 99 1 2 3 4 5 9 ENQ Character number CR LF 9 2 Response...

Page 80: ...code Control Code Hexadecimal Format H Name STX ETX EOT ENQ ACK 02 03 04 05 06 Start of Text End of Text End of Transmission Enquiry Acknowledge 1 No response for line releasing EOT 2 No BCC block che...

Page 81: ...2 4 5 7 RXD TXD RTS CTS SG 2 3 7 8 5 16 5 Connection of RS 485 Screw terminal for I O units a a NC is blank terminal but do not use it as relay terminal a When terminal No 4 and terminal No 5 are sho...

Page 82: ...on resistance is attached to meters connected in two sides of transmit line Please use the cable of 2 wires with shielding wire and attach to host computer in 1 point Interface converter is sold in th...

Page 83: ...ther actions are the same as Ach except for W D comparison character number of response is fixed only respond the indicated value Receive data Function Transfer data Char acter respond the minimal ind...

Page 84: ...A D R 1 9 CR LF D S T H L D W C O A O P B O P Display setting Graph Disp Analog output setting Available when mounted analog output Only when output unit RS 485 Respondecn to the setting in normal act...

Page 85: ...0 0 CR LF Y E S CR LF Motion Detect M D T CR LF M D T O F F CR LF response M D T CR LF M D T T 5 5 W 9 9 CR LF Motion Detect MD Time M D T T 0 CR LF Y E S CR LF setting M D T T 4 5 CR LF Y E S CR LF M...

Page 86: ...9 s respond the setting contents response of BKL 0 means no this function continuously lighting Setting range ON 0 to 4 999 s respond the setting contents respond the setting contents response of PON...

Page 87: ...0 CR LF Y E S CR LF D E F A O P P 1 5 CR LF Y E S CR LF D E F C O N D CR LF Y E S CR LF D E F A L L CR LF Y E S CR LF Setup ALL Output Output Strain Gauge Ach Basic function setting System can be chan...

Page 88: ...ved into FlashROM for each executing 19 1 Analog Input Setting Ach Set items before calibration Calibration is set by items of CA1 and CA2 Though decimal point setting is not performed when setting di...

Page 89: ...F CR LF N CR LF Setting 10 30 300 600 A F B 6 0 0 N CR LF D H I B 9 9 9 9 9 CR LF Set the digital limiter HI N CR LF D L O B 9 9 9 9 9 CR LF Set the digital limiter LI N CR LF S T P B 1 0 CR LF R CR...

Page 90: ...d Error 3 4 Error 5 is cleared Return to the beginning and reset after performing N Reset the SPAN setting value for clearing Error 5 Calibrating setting Actual load setting Function For details of Er...

Page 91: ...CR LF S P A N 5 0 0 0 CR LF Read the SPIN value while N is performed and respond the SPAN setting value before changing Cacel the calibrating of ZERO value skip to setting of SPIN and respond the cur...

Page 92: ...erformed and return to the beginning Error 5 is cleared Setting again is possible Reset the SPN setting value when problem happened Chara cter Return to normal screen after performing R and SAV Receiv...

Page 93: ...LF N CR LF H A L O 0 CR LF 1 0 CR LF H A L O 1 0 CR LF N CR LF H A L L 0 CR LF 1 0 CR LF H A L L 1 0 CR LF N CR LF C O U T 1 CR LF N CR LF Z B N D 0 CR LF 1 0 CR LF Z B N D 1 0 CR LF N CR LF C S R T 1...

Page 94: ...23 24 25 Display seting D S T CR LF P CR LF Graph Disp N CR LF Y S P 1 0 0 CR LF N CR LF Y S C 1 1 0 0 CR LF N CR LF X S P 0 CR LF N CR LF X S C 1 0 CR LF N CR LF I T T 1 0 CR LF 2 0 CR LF I T T 2 0...

Page 95: ...2 I 0 CR LF 1 1 0 5 CR LF S T 2 I 1 1 0 5 CR LF N CR LF S T 2 O 0 CR LF 5 0 0 CR LF S T 2 O 5 0 0 CR LF N CR LF S T 3 I 0 CR LF 1 6 1 0 CR LF S T 3 I 1 6 1 0 CR LF N CR LF S T 3 O 0 CR LF 7 5 0 CR LF...

Page 96: ...T 1 I 5 5 0 CR LF N CR LF S T 1 O 2 5 0 CR LF N CR LF S T 2 I 1 1 0 5 CR LF N CR LF S T 2 O 5 0 0 CR LF N CR LF S T 3 I 1 6 1 0 CR LF N CR LF S T 3 O 7 5 0 CR LF N CR LF S T 4 I 2 2 0 0 CR LF N CR LF...

Page 97: ...RESET Release the control of RS return the control to terminal STB and KEY Release the control of RS for 2 channels return the control to terminal STA STB and KEY NO respond is given when not control...

Page 98: ...Release the control of RS return the control to terminal STOP Respond the operation state Include control terminal KEY RS Digital zero control R Ignore the setting of control terminal and set the usi...

Page 99: ...the display is not in Wave Data Read screen When the cursor is not displayed Respond the Y axis indicated value X axis time Respond the HI Limit HOLD HI waveform setting value Chara cter Receive data...

Page 100: ...F Display screen 1 0 1 1 1 5 CR LF 1 5 0 0 3 2 1 1 CR LF N O CR LF R W P 1 CR LF Y E S CR LF R W H 0 1 0 0 CR LF Y E S CR LF 0 1 0 0 0 CR LF LF 1 1 0 0 2 CR LF LF 1 0 0 1 2 0 0 CR LF LF Set the patter...

Page 101: ...ress setting data Over writing is possible Over writing from midway is possible writing will be resumed Cancel is enabled while in setting 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 2...

Page 102: ...LF Pattern copy for display setting D T C P 1 P 6 CR LF Y E S CR LF Pattern copy for hold setting H D C P 1 P 6 CR LF Y E S CR LF Pattern copy for analog output A O C P 1 1 P 1 5 CR LF Y E S CR LF Pat...

Page 103: ...0 0 0 0 CR LF 5 0 0 0 CR LF A O H I 5 0 0 0 CR LF N A O L O 0 CR LF R CR LF Y E S CR LF BCD output setting B O P CR LF P 1 2 CR LF 8 CR LF P 8 CR LF N CR LF C H N A CR LF B CR LF C H N B CR LF R CR LF...

Page 104: ...s 10V or 20mA Setting range 99999 6 Analog Output LO Set an indicated value when analog output is 0V or 4mA Setting range 99999 Example of analog output setting Set the indicated value when analog out...

Page 105: ...screen Setting items Ach Bch 25 2 Input and Output Specifications 1 Output open collector NPN type BCD signal When logic 1 transistor is ON Polarity POL When minus display transistor is ON Overflow s...

Page 106: ...utput 8 29 Input COM 5 Output 10 30 NC 6 Output 20 31 NC 7 Output 40 32 NC 8 Output 80 33 NC 9 Output 100 34 NC 10 Output 200 35 NC 11 Output 400 36 NC 12 Output 800 37 NC 13 Output 1000 38 NC 14 Outp...

Page 107: ...pe 15 to 17 overlay the message of overflow on screen output HH when overflow and output LL when overflow Set HI and LO to ON when 2 channel Indicated value comparison output don t change when overflo...

Page 108: ...n reset the Error item Normal operation is performed after all Error s are corrected 3 In case of RS 232C the Meter responds at the occurrence of Error when the command is executed As the set value of...

Page 109: ...Function Setting ERROR Hold P00 to 15 HLD P 0 to 15 Graphic Display Setting ERROR Graph Disp P00 to 15 DST P 0 to 15 Waveform Comparison Waveform Displacement Comparison ERROR Waveform P00 to 07 WCO P...

Page 110: ...to 10V Based on digital scaling Approx 1M 30V 0 1 FS 1digit 4 to 20 4 to 20mA Offset 0 to 10000 50 70mA 0 2 FS 1digit 0 to 20 0 to 20mA Full scale 0 to 10000 23 5 35 to 85 RH Nonlinearity Within 0 02...

Page 111: ...is HI GO LO X axis HI LO displacement output SD memory function Can write the reading and writing of setting data of meter and waveform data Option Setting value can be read out Target media 32M 64M 1...

Page 112: ...midity range 0 to 40 35 to 85 RH No dew condensation shall occur Weight Approx 1 0kg Dielectric strength One minute at 500V 1mA DC applied between input AG comparison output E COM RS 232C 485 SG BCD o...

Page 113: ...nit 0 A 20 kg h 40 m h 60 N m2 1 bar 21 kg m2 41 MHz 61 N m 2 22 kg m3 42 m3 h 62 3 cm 23 kHz 43 A 63 oz 4 cm min 24 kJ 44 m 64 Pa 5 deg 25 kN 45 V 65 6 dyne 26 k 46 MJ 66 RH 7 F 27 kPa 47 mm 67 8 ft...

Page 114: ...In this case data of effective inside sampling A D become it after 2 A D sampling Hold signal STA STB terminal Comparison output BCD output Data Pol BCD output PC 1 2 3 4 2 3 4 1 1 2 OFF ON ON OFF 1 S...

Page 115: ...HI HI Limit LL LL Hysteresis LL LL Limit LO LO Hysteresis LO LO Limit LV Minimal Value LV Maximal Value LV Inflection Point LV P Level Time P LV P V Level Time P V Terms in Japanese Terms in English L...

Page 116: ...ment Max Value Always 1 ZOOMx1 START Start Type Step Stop Bit SPAN SET Terms in Japanese Terms in English ZERO Calibration Zero Band Z M Zero Band Zero Band Self Check Sensor Sensor Power Self Check I...

Page 117: ...e Waveform Rejection Data Clear Rejection Data Store Rejection Data Read P V Peak Comparator Type Terms in Japanese Terms in English Start Condition Initialize Comparater Clear Wave Data Pattern Write...

Page 118: ...s carefully inspected and thoroughly tested under a strict quality control before shipment If it does not operate properly please contact the dealer or our company directly to send the Product It is r...