363-206-285
Trouble Clearing:
TAP-101
Issue 2, February 2000
Page 4 of 10
DDM-2000 OC-3 M
ULTIPLEXER
CRITICAL
. CR
LED lighted.
FAULT LED
flashing on DS3
CP.
inc. (from DSX) DS3 LOS*
inc. (from DSX) DS3 OOF*
inc. (from DSX) DS3 sig fail*
Equipment failed or removed at
DSX-3; DS3 input disconnected
at the DSX-3 or at the
DDM-2000 backplane; an
out-of-frame DS3 signal
incoming to the DSX-3 at the far
end; unprotected failure of DS3
CP at the far end or near end;
DS3 signal looped at both ends.
Step 7
CRITICAL
. CR
LED lighted.
FAULT LED
flashing on
STS1E CP.
inc. EC1 LOS*
inc. EC1 LOF*
inc. EC1 sig failed (BER)*
inc. EC1 sig degrade (BER)*
Failure of incoming EC-1 signal
from STSX, failure of STS1E CP
at the near end, failure of
incoming cable or cable
disconnect at EC-1 STSX
cross-connect point or shelf
connector, cross talk in office
wiring,
Step 7
inc. EC1 line AIS*
Failure of the STS1E CP or
equivalent at other end of EC-1
line.
Step 25
inc. STS1 LOP EC1*
Failure of the near-end or
far-end STS1E CP.
Step 25
CRITICAL
.
CR LED lighted.
inc. STS1 AIS*
Incomplete or incorrect
cross-connect provisioning in an
end-to-end network; unprotected
removal or obscure failure of a
DS3, STS1E, MXRVO, or OLIU
CP at the far end; unprotected
optical line failure.
TAP-120
inc. VT AIS*
Incomplete or incorrect
cross-connect provisioning in an
end-to-end network; unprotected
removal or failure of a DS1 CP at
the far end.
TAP-120
inc. STS1 sig failed (BER)
inc. STS1 sig degrade (BER)
Failure of OLIU CP at near end
or far end or failure of receive
fiber.
TAP-111
(linear, 1+1)
or TAP-119
(ring, 0X1)
invalid CP switches
When associated with TIMING
slot, timing mode switch settings
on TGS/TG3 CP are invalid.
Step 14
See notes/footnotes at end of table.
Table A – Critical (CR) Alarm Conditions (Continued)
Alarm Level or
LED Indication
Trouble Description (Note)
Likely causes
Step or
Procedure
Summary of Contents for DDM-2000 OC-3
Page 4: ......
Page 14: ...xiv Issue 3 June 2001 Contents GL Glossary GL 1 ...
Page 24: ...xxiv Issue 3 June 2001 Figures ...
Page 28: ...Tables xxviii Issue 3 June 2001 A A SONET Overview A 34 SONET Transport Rates A 20 ...
Page 58: ...363 206 285 About This Document lviii Issue 3 June 2001 ...
Page 60: ...1 ii Issue 3 June 2001 Table of Contents ...
Page 80: ...363 206 285 System Introduction 1 20 Issue 3 June 2001 ...
Page 154: ...3 ii Issue 3 June 2001 Table of Contents ...
Page 184: ...4 ii Issue 3 June 2001 Table of Contents ...
Page 252: ...363 206 285 Transmission and Synchronization Interfaces 5 60 Issue 3 June 2001 ...
Page 254: ...6 ii Issue 3 June 2001 Table of Contents ...
Page 278: ...7 vi Issue 3 June 2001 Table of Contents ...
Page 436: ...363 206 285 Circuit Pack Descriptions 7 158 Issue 3 June 2001 ...
Page 440: ...8 iv Issue 3 June 2001 Table of Contents ...
Page 518: ...363 206 285 Administration and Provisioning 8 78 Issue 3 June 2001 ...
Page 588: ...10 iv Issue 3 June 2001 Table of Contents ...
Page 690: ...363 206 285 Commands and Reports 11 20 Issue 2 February 2000 ...
Page 1252: ...11 582 2000 February 2 Issue OC 3 DDM 2000 ...
Page 1254: ...A ii Issue 3 June 2001 Table of Contents ...
Page 1276: ...363 206 285 A SONET Overview A 22 Issue 3 June 2001 ...
Page 1316: ......
Page 1348: ...363 206 285 Acceptance IXL 001 Issue 3 June 2001 Page 2 of 2 DDM 2000 OC 3 MULTIPLEXER ...
Page 1412: ...NTP 003 System Turnup 363 206 285 Page 6 of 6 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 1420: ...363 206 285 System Turnup NTP 004 Issue 2 February 2000 Page 8 of 8 DDM 2000 OC 3 MULTIPLEXER ...
Page 1440: ...NTP 008 Circuit Order 363 206 285 Page 6 of 6 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 1458: ...363 206 285 Circuit Order NTP 011 Issue 2 February 2000 Page 6 of 6 DDM 2000 OC 3 MULTIPLEXER ...
Page 1462: ...NTP 012 Circuit Order 363 206 285 Page 4 of 4 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 1464: ...NTP 013 Circuit Order 363 206 285 Page 2 of 2 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 1508: ...363 206 285 System Turnup NTP 020 Issue 2 February 2000 Page 8 of 8 DDM 2000 OC 3 MULTIPLEXER ...
Page 1512: ...NTP 021 Circuit Order 363 206 285 Page 4 of 4 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 1528: ...363 206 285 Circuit Order NTP 023 Issue 2 February 2000 Page 8 of 8 DDM 2000 OC 3 MULTIPLEXER ...
Page 1560: ...363 206 285 Circuit Order NTP 025 Issue 2 February 2000 Page 8 of 8 DDM 2000 OC 3 MULTIPLEXER ...
Page 1574: ...363 206 285 Circuit Order NTP 027 Issue 2 February 2000 Page 4 of 4 DDM 2000 OC 3 MULTIPLEXER ...
Page 1610: ...363 206 285 Circuit Order NTP 030 Issue 2 February 2000 Page 8 of 8 DDM 2000 OC 3 MULTIPLEXER ...
Page 1616: ...363 206 285 Circuit Order NTP 031 Issue 2 February 2000 Page 6 of 6 DDM 2000 OC 3 MULTIPLEXER ...
Page 1622: ...363 206 285 Circuit Order NTP 032 Issue 2 February 2000 Page 6 of 6 DDM 2000 OC 3 MULTIPLEXER ...
Page 1634: ...363 206 285 System Turnup NTP 034 Issue 2 February 2000 Page 6 of 6 DDM 2000 OC 3 MULTIPLEXER ...
Page 1652: ...363 206 285 Circuit Order NTP 038 Issue 2 February 2000 Page 6 of 6 DDM 2000 OC 3 MULTIPLEXER ...
Page 1702: ...363 206 285 System Turnup NTP 041 Issue 2 February 2000 Page 8 of 8 DDM 2000 OC 3 MULTIPLEXER ...
Page 1744: ...NTP 045 System Turnup 363 206 285 Page 8 of 8 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 1808: ...363 206 285 Circuit Order NTP 052 Issue 2 February 2000 Page 6 of 6 DDM 2000 OC 3 MULTIPLEXER ...
Page 1866: ...363 206 285 System Turnup NTP 057 Issue 3 June 2001 Page 12 of 12 DDM 2000 OC 3 MULTIPLEXER ...
Page 1884: ...363 206 285 System Turnup NTP 059 Issue 3 June 2001 Page 12 of 12 DDM 2000 OC 3 MULTIPLEXER ...
Page 1912: ...NTP 002 Operation 363 206 285 Page 2 of 2 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 2530: ...363 206 285 Page 2 of 2 Issue 3 June 2001 DDM 2000 OC 3 MULTIPLEXER ...