363-206-285
Administration and Provisioning
8-40
Issue 3
June 2001
OC-3/OC-12 Path Protected Ring Drop and
Continue Application
8
This is a path protected ring application with multiple NEs in a two-fiber ring. All
but two nodes are normal ring application nodes (see previous application). Two
nodes are defined to be the drop and continue nodes and are neighbors. They
function to provide two copies of each service on the ring to another ring (dual ring
interworking) or to wire centers (dual wire center service). Special drop and
continue cross-connections are used to support this feature. The STS1E low-
speed circuit pack is used to transport traffic between rings or to the wire centers.
This feature provides node failure survival functionality. These two special nodes
can also provide normal ring functionality at the same time.
OC-3/OC-12 Path Protected Ring Cross-Connect
Restrictions
8
Restrictions on path-protected ring cross-connections include the following:
■
All VT-1.5 cross-connections (
ent-crs-vt1
) are done via the OLIU circuit
packs in the main slots. The OLIU circuit packs must be 22-type, 24-type,
26G2-U, 27G-U or 29-type.
■
Time slots in function units A and B cannot be cross-connected to each
other.
■
When function units A and B are equipped with OLIUs, they can only carry
two STS-1 or 56 VT1.5 signals. They cannot be cross-connected with main
or function unit C to carry three STS-1, 84 VT1.5 or an STS3C signal.
■
A cross-connection cannot be made to a slot that is in the unequipped
state. Also, a cross-connection may not be made with any signal where a
cross-connection already exists. The existing cross-connection must be
deleted before a new cross-connection can be entered.
■
If the system is equipped with OLIUs in function unit A and/or B, only one
STS-1 signal per function unit is allowed to be connected (added) to
function unit C.
■
For VT1.5 cross-connections, all drop and continue cross-connections on a
shelf must be entered into the same ring.
■
Use the following rules to establish cross-connections in each ring:
a.
All drop connections (including DRI, if present) from the same ring
must be provisioned the same, either all VT1.5 or all STS-1.
b.
If all 28 VT1.5s (DS1s) in an STS-1 are being passed through at a
node in a VT1.5 path-switched ring, the cross-connection may be
provisioned as either a pass-through STS-1 or VT1.5. However, if
you anticipate dropping VT1.5s from the pass-through node, you
should provision the pass-throughs as VT1.5 cross-connections.
Summary of Contents for DDM-2000 OC-3
Page 4: ......
Page 14: ...xiv Issue 3 June 2001 Contents GL Glossary GL 1 ...
Page 24: ...xxiv Issue 3 June 2001 Figures ...
Page 28: ...Tables xxviii Issue 3 June 2001 A A SONET Overview A 34 SONET Transport Rates A 20 ...
Page 58: ...363 206 285 About This Document lviii Issue 3 June 2001 ...
Page 60: ...1 ii Issue 3 June 2001 Table of Contents ...
Page 80: ...363 206 285 System Introduction 1 20 Issue 3 June 2001 ...
Page 154: ...3 ii Issue 3 June 2001 Table of Contents ...
Page 184: ...4 ii Issue 3 June 2001 Table of Contents ...
Page 252: ...363 206 285 Transmission and Synchronization Interfaces 5 60 Issue 3 June 2001 ...
Page 254: ...6 ii Issue 3 June 2001 Table of Contents ...
Page 278: ...7 vi Issue 3 June 2001 Table of Contents ...
Page 436: ...363 206 285 Circuit Pack Descriptions 7 158 Issue 3 June 2001 ...
Page 440: ...8 iv Issue 3 June 2001 Table of Contents ...
Page 518: ...363 206 285 Administration and Provisioning 8 78 Issue 3 June 2001 ...
Page 588: ...10 iv Issue 3 June 2001 Table of Contents ...
Page 690: ...363 206 285 Commands and Reports 11 20 Issue 2 February 2000 ...
Page 1252: ...11 582 2000 February 2 Issue OC 3 DDM 2000 ...
Page 1254: ...A ii Issue 3 June 2001 Table of Contents ...
Page 1276: ...363 206 285 A SONET Overview A 22 Issue 3 June 2001 ...
Page 1316: ......
Page 1348: ...363 206 285 Acceptance IXL 001 Issue 3 June 2001 Page 2 of 2 DDM 2000 OC 3 MULTIPLEXER ...
Page 1412: ...NTP 003 System Turnup 363 206 285 Page 6 of 6 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 1420: ...363 206 285 System Turnup NTP 004 Issue 2 February 2000 Page 8 of 8 DDM 2000 OC 3 MULTIPLEXER ...
Page 1440: ...NTP 008 Circuit Order 363 206 285 Page 6 of 6 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 1458: ...363 206 285 Circuit Order NTP 011 Issue 2 February 2000 Page 6 of 6 DDM 2000 OC 3 MULTIPLEXER ...
Page 1462: ...NTP 012 Circuit Order 363 206 285 Page 4 of 4 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 1464: ...NTP 013 Circuit Order 363 206 285 Page 2 of 2 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 1508: ...363 206 285 System Turnup NTP 020 Issue 2 February 2000 Page 8 of 8 DDM 2000 OC 3 MULTIPLEXER ...
Page 1512: ...NTP 021 Circuit Order 363 206 285 Page 4 of 4 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 1528: ...363 206 285 Circuit Order NTP 023 Issue 2 February 2000 Page 8 of 8 DDM 2000 OC 3 MULTIPLEXER ...
Page 1560: ...363 206 285 Circuit Order NTP 025 Issue 2 February 2000 Page 8 of 8 DDM 2000 OC 3 MULTIPLEXER ...
Page 1574: ...363 206 285 Circuit Order NTP 027 Issue 2 February 2000 Page 4 of 4 DDM 2000 OC 3 MULTIPLEXER ...
Page 1610: ...363 206 285 Circuit Order NTP 030 Issue 2 February 2000 Page 8 of 8 DDM 2000 OC 3 MULTIPLEXER ...
Page 1616: ...363 206 285 Circuit Order NTP 031 Issue 2 February 2000 Page 6 of 6 DDM 2000 OC 3 MULTIPLEXER ...
Page 1622: ...363 206 285 Circuit Order NTP 032 Issue 2 February 2000 Page 6 of 6 DDM 2000 OC 3 MULTIPLEXER ...
Page 1634: ...363 206 285 System Turnup NTP 034 Issue 2 February 2000 Page 6 of 6 DDM 2000 OC 3 MULTIPLEXER ...
Page 1652: ...363 206 285 Circuit Order NTP 038 Issue 2 February 2000 Page 6 of 6 DDM 2000 OC 3 MULTIPLEXER ...
Page 1702: ...363 206 285 System Turnup NTP 041 Issue 2 February 2000 Page 8 of 8 DDM 2000 OC 3 MULTIPLEXER ...
Page 1744: ...NTP 045 System Turnup 363 206 285 Page 8 of 8 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 1808: ...363 206 285 Circuit Order NTP 052 Issue 2 February 2000 Page 6 of 6 DDM 2000 OC 3 MULTIPLEXER ...
Page 1866: ...363 206 285 System Turnup NTP 057 Issue 3 June 2001 Page 12 of 12 DDM 2000 OC 3 MULTIPLEXER ...
Page 1884: ...363 206 285 System Turnup NTP 059 Issue 3 June 2001 Page 12 of 12 DDM 2000 OC 3 MULTIPLEXER ...
Page 1912: ...NTP 002 Operation 363 206 285 Page 2 of 2 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 2530: ...363 206 285 Page 2 of 2 Issue 3 June 2001 DDM 2000 OC 3 MULTIPLEXER ...