363-206-285
Trouble Clearing:
TAP-120
Issue 2, February 2000
Page 2 of 4
DDM-2000 OC-3 M
ULTIPLEXER
4.
Were there incomplete or incorrect cross-connects?
If YES, then continue with Step 5.
If NO, then proceed to Step 7.
5.
Use the commands
ent-crs-sts1:
and
dlt-crs-sts1:
, as necessary, to
correct the provisioning.
6.
Have all indications of STS1 AIS cleared?
If YES, then STOP. YOU HAVE COMPLETED THIS PROCEDURE.
If NO, then continue with Step 7.
7.
NOTE:
If the service is STS1 cross-connected at either terminating shelf, both
terminating shelves must be properly equipped to terminate the entire
STS1. For example, if DS1 service is being provided, both ends must be
equipped with MXRVO circuit packs and the same number of
DS1/DS1PM circuit packs in the groups that are STS1 cross-connected.
Use the
rtrv-eqpt:
command at both shelves to verify that the shelves are
properly equipped for the service being provided. If the shelves are not
properly equipped, install circuit packs as required.
8.
Have all indications of STS1 AIS cleared?
If YES, then STOP. YOU HAVE COMPLETED THIS PROCEDURE.
If NO, then continue with Step 9.
9.
Using the
rlgn
command, where possible, or have the central maintenance
center login to every shelf where the service should be pass-through
cross-connected (for example, m-1 to c-1) and use the
rtrv-crs-sts1:
command to determine if the time slot identified in Step 2 is cross-connected
as specified in circuit layout or other office records. If service is
cross-connected through other maintenance subnetworks, such as dual ring
interworking (DRI), look for missing cross-connections in the other
subnetworks.
10. At any shelves with missing cross-connects use the
ent-crs-sts1:
command to provision the pass-through cross-connect (for example, m-1 to
c-1).
11. STOP. YOU HAVE COMPLETED THIS PROCEDURE.
Summary of Contents for DDM-2000 OC-3
Page 4: ......
Page 14: ...xiv Issue 3 June 2001 Contents GL Glossary GL 1 ...
Page 24: ...xxiv Issue 3 June 2001 Figures ...
Page 28: ...Tables xxviii Issue 3 June 2001 A A SONET Overview A 34 SONET Transport Rates A 20 ...
Page 58: ...363 206 285 About This Document lviii Issue 3 June 2001 ...
Page 60: ...1 ii Issue 3 June 2001 Table of Contents ...
Page 80: ...363 206 285 System Introduction 1 20 Issue 3 June 2001 ...
Page 154: ...3 ii Issue 3 June 2001 Table of Contents ...
Page 184: ...4 ii Issue 3 June 2001 Table of Contents ...
Page 252: ...363 206 285 Transmission and Synchronization Interfaces 5 60 Issue 3 June 2001 ...
Page 254: ...6 ii Issue 3 June 2001 Table of Contents ...
Page 278: ...7 vi Issue 3 June 2001 Table of Contents ...
Page 436: ...363 206 285 Circuit Pack Descriptions 7 158 Issue 3 June 2001 ...
Page 440: ...8 iv Issue 3 June 2001 Table of Contents ...
Page 518: ...363 206 285 Administration and Provisioning 8 78 Issue 3 June 2001 ...
Page 588: ...10 iv Issue 3 June 2001 Table of Contents ...
Page 690: ...363 206 285 Commands and Reports 11 20 Issue 2 February 2000 ...
Page 1252: ...11 582 2000 February 2 Issue OC 3 DDM 2000 ...
Page 1254: ...A ii Issue 3 June 2001 Table of Contents ...
Page 1276: ...363 206 285 A SONET Overview A 22 Issue 3 June 2001 ...
Page 1316: ......
Page 1348: ...363 206 285 Acceptance IXL 001 Issue 3 June 2001 Page 2 of 2 DDM 2000 OC 3 MULTIPLEXER ...
Page 1412: ...NTP 003 System Turnup 363 206 285 Page 6 of 6 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 1420: ...363 206 285 System Turnup NTP 004 Issue 2 February 2000 Page 8 of 8 DDM 2000 OC 3 MULTIPLEXER ...
Page 1440: ...NTP 008 Circuit Order 363 206 285 Page 6 of 6 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 1458: ...363 206 285 Circuit Order NTP 011 Issue 2 February 2000 Page 6 of 6 DDM 2000 OC 3 MULTIPLEXER ...
Page 1462: ...NTP 012 Circuit Order 363 206 285 Page 4 of 4 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 1464: ...NTP 013 Circuit Order 363 206 285 Page 2 of 2 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 1508: ...363 206 285 System Turnup NTP 020 Issue 2 February 2000 Page 8 of 8 DDM 2000 OC 3 MULTIPLEXER ...
Page 1512: ...NTP 021 Circuit Order 363 206 285 Page 4 of 4 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 1528: ...363 206 285 Circuit Order NTP 023 Issue 2 February 2000 Page 8 of 8 DDM 2000 OC 3 MULTIPLEXER ...
Page 1560: ...363 206 285 Circuit Order NTP 025 Issue 2 February 2000 Page 8 of 8 DDM 2000 OC 3 MULTIPLEXER ...
Page 1574: ...363 206 285 Circuit Order NTP 027 Issue 2 February 2000 Page 4 of 4 DDM 2000 OC 3 MULTIPLEXER ...
Page 1610: ...363 206 285 Circuit Order NTP 030 Issue 2 February 2000 Page 8 of 8 DDM 2000 OC 3 MULTIPLEXER ...
Page 1616: ...363 206 285 Circuit Order NTP 031 Issue 2 February 2000 Page 6 of 6 DDM 2000 OC 3 MULTIPLEXER ...
Page 1622: ...363 206 285 Circuit Order NTP 032 Issue 2 February 2000 Page 6 of 6 DDM 2000 OC 3 MULTIPLEXER ...
Page 1634: ...363 206 285 System Turnup NTP 034 Issue 2 February 2000 Page 6 of 6 DDM 2000 OC 3 MULTIPLEXER ...
Page 1652: ...363 206 285 Circuit Order NTP 038 Issue 2 February 2000 Page 6 of 6 DDM 2000 OC 3 MULTIPLEXER ...
Page 1702: ...363 206 285 System Turnup NTP 041 Issue 2 February 2000 Page 8 of 8 DDM 2000 OC 3 MULTIPLEXER ...
Page 1744: ...NTP 045 System Turnup 363 206 285 Page 8 of 8 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 1808: ...363 206 285 Circuit Order NTP 052 Issue 2 February 2000 Page 6 of 6 DDM 2000 OC 3 MULTIPLEXER ...
Page 1866: ...363 206 285 System Turnup NTP 057 Issue 3 June 2001 Page 12 of 12 DDM 2000 OC 3 MULTIPLEXER ...
Page 1884: ...363 206 285 System Turnup NTP 059 Issue 3 June 2001 Page 12 of 12 DDM 2000 OC 3 MULTIPLEXER ...
Page 1912: ...NTP 002 Operation 363 206 285 Page 2 of 2 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 2530: ...363 206 285 Page 2 of 2 Issue 3 June 2001 DDM 2000 OC 3 MULTIPLEXER ...