363-206-285
Maintenance Description
Issue 3
June 2001
9-45
C-Bit
9
When the DS3 path PM C-bit option is selected, both near-end and far-end (far-
end block errors — FEBE) PM data are monitored and displayed.
The system provides counts of DS3 C-bit parity coding violations (CV-P), ES-P,
SES-P, and UAS-P incoming from both the DSX-3 and the fiber. The type of PM is
provisioned per DS3 service by a CIT command.
For C-bit PM, the DS3 service can be provisioned in violation monitor (VM) or
violation monitor and removal (VMR) modes. In VMR mode, the C-bit errors are
not corrected as in the P-bit option.
Quarter-hour and day registers are provided with provisionable TCAs. The TCAs
are provisionable on a per-shelf basis. SEFS counts are also provided.
DS3 Line
9
DS3 line parameters include line coding violations (CVL), errored seconds (ESL),
and severely errored seconds (SESL). DS3 line PM provides provisionable bit
error ratios (TCAs) for all DS3 line parameters. For CVL parameters, bit errors
can also be provisioned in ratios such as 10
-7
, 10
-8
and 10
-9
.
Optical Parameters
9
Performance Monitoring Enabling
9
Collection of optical parameters are initiated when a slot is equipped with an OLIU
circuit pack. Parameters continue to be available in reports and generate
appropriate TCAs until the OLIU is removed and the
update
command or the
UPD/INIT button is pressed.
Laser Bias Current
9
The laser bias current is monitored continuously to detect degraded performance
of the laser. A TCA is generated if the laser bias current exceeds a fixed threshold
of 1.5 times the nominal value. Laser bias current is monitored independently for
service and protection optical facilities.
Optical Transmit Power
9
The optical transmit power is monitored continuously to detect degraded
performance of the laser. Threshold-crossing alerts (TCAs) are generated if the
optical transmit power falls below fixed thresholds of
−
1 dB and
−
2 dB. Optical
Summary of Contents for DDM-2000 OC-3
Page 4: ......
Page 14: ...xiv Issue 3 June 2001 Contents GL Glossary GL 1 ...
Page 24: ...xxiv Issue 3 June 2001 Figures ...
Page 28: ...Tables xxviii Issue 3 June 2001 A A SONET Overview A 34 SONET Transport Rates A 20 ...
Page 58: ...363 206 285 About This Document lviii Issue 3 June 2001 ...
Page 60: ...1 ii Issue 3 June 2001 Table of Contents ...
Page 80: ...363 206 285 System Introduction 1 20 Issue 3 June 2001 ...
Page 154: ...3 ii Issue 3 June 2001 Table of Contents ...
Page 184: ...4 ii Issue 3 June 2001 Table of Contents ...
Page 252: ...363 206 285 Transmission and Synchronization Interfaces 5 60 Issue 3 June 2001 ...
Page 254: ...6 ii Issue 3 June 2001 Table of Contents ...
Page 278: ...7 vi Issue 3 June 2001 Table of Contents ...
Page 436: ...363 206 285 Circuit Pack Descriptions 7 158 Issue 3 June 2001 ...
Page 440: ...8 iv Issue 3 June 2001 Table of Contents ...
Page 518: ...363 206 285 Administration and Provisioning 8 78 Issue 3 June 2001 ...
Page 588: ...10 iv Issue 3 June 2001 Table of Contents ...
Page 690: ...363 206 285 Commands and Reports 11 20 Issue 2 February 2000 ...
Page 1252: ...11 582 2000 February 2 Issue OC 3 DDM 2000 ...
Page 1254: ...A ii Issue 3 June 2001 Table of Contents ...
Page 1276: ...363 206 285 A SONET Overview A 22 Issue 3 June 2001 ...
Page 1316: ......
Page 1348: ...363 206 285 Acceptance IXL 001 Issue 3 June 2001 Page 2 of 2 DDM 2000 OC 3 MULTIPLEXER ...
Page 1412: ...NTP 003 System Turnup 363 206 285 Page 6 of 6 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 1420: ...363 206 285 System Turnup NTP 004 Issue 2 February 2000 Page 8 of 8 DDM 2000 OC 3 MULTIPLEXER ...
Page 1440: ...NTP 008 Circuit Order 363 206 285 Page 6 of 6 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 1458: ...363 206 285 Circuit Order NTP 011 Issue 2 February 2000 Page 6 of 6 DDM 2000 OC 3 MULTIPLEXER ...
Page 1462: ...NTP 012 Circuit Order 363 206 285 Page 4 of 4 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 1464: ...NTP 013 Circuit Order 363 206 285 Page 2 of 2 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 1508: ...363 206 285 System Turnup NTP 020 Issue 2 February 2000 Page 8 of 8 DDM 2000 OC 3 MULTIPLEXER ...
Page 1512: ...NTP 021 Circuit Order 363 206 285 Page 4 of 4 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 1528: ...363 206 285 Circuit Order NTP 023 Issue 2 February 2000 Page 8 of 8 DDM 2000 OC 3 MULTIPLEXER ...
Page 1560: ...363 206 285 Circuit Order NTP 025 Issue 2 February 2000 Page 8 of 8 DDM 2000 OC 3 MULTIPLEXER ...
Page 1574: ...363 206 285 Circuit Order NTP 027 Issue 2 February 2000 Page 4 of 4 DDM 2000 OC 3 MULTIPLEXER ...
Page 1610: ...363 206 285 Circuit Order NTP 030 Issue 2 February 2000 Page 8 of 8 DDM 2000 OC 3 MULTIPLEXER ...
Page 1616: ...363 206 285 Circuit Order NTP 031 Issue 2 February 2000 Page 6 of 6 DDM 2000 OC 3 MULTIPLEXER ...
Page 1622: ...363 206 285 Circuit Order NTP 032 Issue 2 February 2000 Page 6 of 6 DDM 2000 OC 3 MULTIPLEXER ...
Page 1634: ...363 206 285 System Turnup NTP 034 Issue 2 February 2000 Page 6 of 6 DDM 2000 OC 3 MULTIPLEXER ...
Page 1652: ...363 206 285 Circuit Order NTP 038 Issue 2 February 2000 Page 6 of 6 DDM 2000 OC 3 MULTIPLEXER ...
Page 1702: ...363 206 285 System Turnup NTP 041 Issue 2 February 2000 Page 8 of 8 DDM 2000 OC 3 MULTIPLEXER ...
Page 1744: ...NTP 045 System Turnup 363 206 285 Page 8 of 8 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 1808: ...363 206 285 Circuit Order NTP 052 Issue 2 February 2000 Page 6 of 6 DDM 2000 OC 3 MULTIPLEXER ...
Page 1866: ...363 206 285 System Turnup NTP 057 Issue 3 June 2001 Page 12 of 12 DDM 2000 OC 3 MULTIPLEXER ...
Page 1884: ...363 206 285 System Turnup NTP 059 Issue 3 June 2001 Page 12 of 12 DDM 2000 OC 3 MULTIPLEXER ...
Page 1912: ...NTP 002 Operation 363 206 285 Page 2 of 2 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 2530: ...363 206 285 Page 2 of 2 Issue 3 June 2001 DDM 2000 OC 3 MULTIPLEXER ...