[26] RC gateway function commands
474
z
RPCR (Clear RC-axis position data)
*1 439 RC Position Data Use Method Error when
a command was executed
XSEL
{
Can be used
RC position-data
use mode
RC
u
Cannot be used
*1
Command, declaration
Extension
condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
operation type
(Output, flag)
E
N, Cnd
Cmnd
Operand 1
Operand 2
Pst
Optional Optional
RPCR
RC-axis
number
Variable
number
CP
Applicable models
XSEL
-J/K
XSEL
-P/Q/
PCT/QCT
XSEL
-R/S
XSEL
-JX/KX
XSEL
-PX/QX
XSEL
-RX/SX/
RXD/SXD
ASEL
PSEL
SSEL
TT/TTA MSEL
u
{
{
u
{
{
u
u
u
[Function]
Clear position data in the range specified by variable No. n and variable No. n+1.
After the data is cleared, the fields become blank.
Variable
b
Description of setting
n
Clear start position number
n+1
Clear end position number
[Example 1]
LET
200
0
Assign 0 to variable 200.
LET
201
1
Assign 1 to variable 201.
RPCR
1
200
Clear 1 from position No. 0 of axis 1.
0.10
0
0.3
300
200.00
2
1
0
Inp
Push
Acc
Vel
Pos
No.
Cleared.
Position data of axis 1
Summary of Contents for PSEL
Page 2: ......
Page 10: ......
Page 18: ...8 Part 1 Installation ...
Page 37: ...27 Part 1 Installation 2 2 axis specification with battery ...
Page 382: ...372 Appendix Micro cylinder RCL Series Current limiting value ratio Push force N ...
Page 476: ...466 Appendix ...
Page 480: ...470 ...
Page 485: ...475 ...
Page 487: ...INTELLIGENT ACTUATOR SEL Language Programming Manual Eighth Edition ...
Page 488: ......
Page 490: ......
Page 494: ......
Page 518: ...24 ...
Page 526: ...32 ...
Page 831: ... 11 Actuator Control Declaration 337 Example DFIF 1 170 ...
Page 1060: ......
Page 1061: ......