SCRV (Set sigmoid motion ratio)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
Optional Optional
SCRV
Ratio
Prohibited CP
[Function] Set the ratio of sigmoid motion control of the actuator in the value specified in operand 1.
The ratio is set as an integer in a range from 0 to 50 (%).
a
b
X 100 (%)
If the ratio is not set using this command or 0% is set, a trapezoid motion will be
implemented.
A SCRV command can be used with the following commands:
MOVP, MOVL, MVPI, MVLI, JBWF, JBWN, JFWF, JFWN
MOVD,
MVDI
[Example 1]
SCRV
30
Set the sigmoid motion ratio to 30%.
a
b
Speed
Time