[16] System Information
Acquisition
402
z
PGST (Get program status)
Command, declaration
Extension
condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
E
N, Cnd
Cmnd
Operand 1
Operand 2
Pst
Optional Optional
PGST
Variable
number
Program
number
CP
Applicable models
All models [Refer to Section 5.1 for details of models]
{
[Function]
Store in the variable specified in operand 1 the status (program error number) of
the program specified in operand 2.
(Note 1)
If the obtained result is “0”, it means no program error is present.
(Note 2)
Although the error lists are written in hexadecimals, the status to be stored
(program error number) is a decimal.
Therefore, the decimal program error numbers must be converted to
hexadecimals.
[Example]
PGST
1
2
Read the error number for program No. 2 to
variable 1.