181
Part 2 Programs
z
PTRQ (Change push torque limit parameter)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
Optional Optional
PTRQ
Axis
pattern
Ratio CC
[Function] Change the push torque limit parameter of the axis pattern specified in operand 1 to the value
in operand 2. Operand 2 is set as an integer (unit: %).
A PTRQ command temporarily rewrites “Driver parameter No. 38: Push torque limit at
positioning.”
(Note 1)
If a push torque limit is not set by a PTRQ command, the value set in “Driver parameter No.
38: Push torque limit at positioning” will be used.
(Note 2)
The new push torque limit will remain effective even after the program ends. Therefore, when
building a system using the PTRQ command, in every program explicitly specify a push
torque limit using a PTRQ command before each push-motion operation. Assuming that the
push torque limit will be reset to the original value when push-motion operation ends in one
program can cause an unexpected problem in another program, because a different push
torque limit will be used if the program is aborted due to an error, etc.
(Note 3)
The new value set by a PTRQ command will become ineffective after a power-on reset or
software reset.
(Note 4)
A PTRQ command does not rewrite “Driver parameter No. 38: Push torque limit at
positioning” (main CPU flash memory (non-volatile memory)).
[Example]
PTRQ
1
50
Change the push torque limit parameter for axis 1 to 50%.
PAPR
100
20
Set the push-motion approach distance to 100 mm and the
push-motion approach speed to 20 mm/sec.
MOVP
2
Move to position No. 2.
PUSH
10
Move by push motion from position No. 2 to position No. 10.
Summary of Contents for PSEL
Page 2: ......
Page 10: ......
Page 18: ...8 Part 1 Installation ...
Page 37: ...27 Part 1 Installation 2 2 axis specification with battery ...
Page 382: ...372 Appendix Micro cylinder RCL Series Current limiting value ratio Push force N ...
Page 476: ...466 Appendix ...
Page 480: ...470 ...
Page 485: ...475 ...
Page 487: ...INTELLIGENT ACTUATOR SEL Language Programming Manual Eighth Edition ...
Page 488: ......
Page 490: ......
Page 494: ......
Page 518: ...24 ...
Page 526: ...32 ...
Page 831: ... 11 Actuator Control Declaration 337 Example DFIF 1 170 ...
Page 1060: ......
Page 1061: ......