112
Part 2 Programs
z
EOR (Logical exclusive-OR)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
Optional Optional EOR
Variable
number
Data ZR
[Function]
Assign the logical exclusive-OR operation result of the content of the variable specified in
operand 1 and the value specified in operand 2, to the variable specified in operand 1.
The output will turn ON when the operation result becomes 0.
[Example 1]
LET
1
204
Assign 204 to variable 1.
EOR
1
170
Assign the logical exclusive-OR operation result
(102) of the content of variable 1 (204) and 170, to
variable 1.
[Example 2]
LET
1
204
Assign 204 to variable 1.
LET
3
170
Assign 170 to variable 3.
EOR
1
*3
Assign the logical exclusive-OR operation result
(102) of the content of variable 1 (204) and the
content of variable 3 (170) to variable 1.
Decimal Binary
204
EOR 170
102
11001100
EOR 10101010
01100110
Summary of Contents for PSEL
Page 2: ......
Page 10: ......
Page 18: ...8 Part 1 Installation ...
Page 37: ...27 Part 1 Installation 2 2 axis specification with battery ...
Page 382: ...372 Appendix Micro cylinder RCL Series Current limiting value ratio Push force N ...
Page 476: ...466 Appendix ...
Page 480: ...470 ...
Page 485: ...475 ...
Page 487: ...INTELLIGENT ACTUATOR SEL Language Programming Manual Eighth Edition ...
Page 488: ......
Page 490: ......
Page 494: ......
Page 518: ...24 ...
Page 526: ...32 ...
Page 831: ... 11 Actuator Control Declaration 337 Example DFIF 1 170 ...
Page 1060: ......
Page 1061: ......