Actuator Control Command
365
z
PTRQ (Change push torque limit parameter)
Command, declaration
Extension
condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
E
N, Cnd
Cmnd
Operand 1
Operand 2
Pst
Optional Optional
PTRQ
Axis
pattern
Ratio CC
Applicable models
XSEL-J/K
u
Other than XSEL-J/K
{
[Function]
Change the push torque limit parameter of the axis pattern specified in operand 1
to the value in operand 2. Operand 2 is set as an integer (unit: %).
A PTRQ command temporarily rewrites “Driver parameter No. 38: Push torque
limit at positioning”.
(Note 1)
If a push torque limit is not set by a PTRQ command, the value set in “Driver
parameter No. 38: Push torque limit at positioning” will be used.
(Note 2)
The new push torque limit will remain effective even after the program ends.
Therefore, when building a system using the PTRQ command, in every program
explicitly specify a push torque limit using a PTRQ command before each
push-motion operation. Assuming that the push torque limit will be reset to the
original value when push-motion operation ends in one program can cause an
unexpected problem in another program, because a different push torque limit will
be used if the program is aborted due to an error, etc.
(Note 3)
The new value set by a PTRQ command will become ineffective after a power ON
reset or software reset.
(Note 4)
A PTRQ command does not rewrite “Driver parameter No. 38: Push torque limit at
positioning” (main CPU flash memory (non-volatile memory)).
[Example]
PTRQ 1
50
Change the push torque limit parameter for axis 1 to
50%.
PAPR
100
20
Set the push-motion approach distance to 100mm
and the push-motion approach speed to 20mm/sec.
MOVP 2
Move to position No. 2.
PUSH 10
Move by push motion from position No. 2 to position
No. 10.
Summary of Contents for PSEL
Page 2: ......
Page 10: ......
Page 18: ...8 Part 1 Installation ...
Page 37: ...27 Part 1 Installation 2 2 axis specification with battery ...
Page 382: ...372 Appendix Micro cylinder RCL Series Current limiting value ratio Push force N ...
Page 476: ...466 Appendix ...
Page 480: ...470 ...
Page 485: ...475 ...
Page 487: ...INTELLIGENT ACTUATOR SEL Language Programming Manual Eighth Edition ...
Page 488: ......
Page 490: ......
Page 494: ......
Page 518: ...24 ...
Page 526: ...32 ...
Page 831: ... 11 Actuator Control Declaration 337 Example DFIF 1 170 ...
Page 1060: ......
Page 1061: ......