2. Connection with Host System
93
XSEL-R/S/RX/SX/RXD/SXD Virtual Input Ports (Internal Flags)
Port No.
Function
7076
Tracking Operation Complete Work Position Arrival Latch Signal (Latches until “TRAC 1 nnn” or “Tracking
Operation Execution Program Finish”)
7077
In Tracking Conveyor Tracking Complete Range
7078
Tracking Reversed Operation Detected Work Position Arrival Latch Signal (Latches until “TRAC 1 nnn” or
“Tracking Operation Execution Program Finish”)
7079
During Tracking Mode (Work detection valid) (for SCARA controller only)
7080
During Tracking Operation (including a pause in tracking operation)
7081 to 7100 (Reserved by the system = Use is strictly prohibited)
7101
Program No. 01 is being executed (or paused).
7102
Program No. 02 is being executed (or paused).
7103
Program No. 03 is being executed (or paused).
~ ~
7227
Program No. 127 is being executed (or paused).
7228
Program No. 128 is being executed (or paused).
7229 to 7299 (Reserved by the system = Use is strictly prohibited)
Summary of Contents for PSEL
Page 2: ......
Page 10: ......
Page 18: ...8 Part 1 Installation ...
Page 37: ...27 Part 1 Installation 2 2 axis specification with battery ...
Page 382: ...372 Appendix Micro cylinder RCL Series Current limiting value ratio Push force N ...
Page 476: ...466 Appendix ...
Page 480: ...470 ...
Page 485: ...475 ...
Page 487: ...INTELLIGENT ACTUATOR SEL Language Programming Manual Eighth Edition ...
Page 488: ......
Page 490: ......
Page 494: ......
Page 518: ...24 ...
Page 526: ...32 ...
Page 831: ... 11 Actuator Control Declaration 337 Example DFIF 1 170 ...
Page 1060: ......
Page 1061: ......