[6] T
imer
248
[6] Timer
z
TIMW (Timer)
Command, declaration
Extension
condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
E
N, Cnd
Cmnd
Operand 1
Operand 2
Pst
Optional Optional
TIMW
Time
Prohibited
TU
Applicable models
All models [Refer to Section 5.1 for details of models]
{
[Function]
Stop the program and wait for the time specified in operand 1.
The setting range is 0.01 to 99, and the unit is second.
The output will turn ON when the specified time has elapsed and the program
proceeds to the next step.
[Example 1]
TIMW
1.5
Wait for 1.5sec.
[Example 2]
LET
1
10
Assign 10 to variable 1.
TIMW
*1
Wait for the content of variable 1 (10sec).