425
Appendix
Other Parameters
No. Parameter
name
Default value
(Reference)
Input range
Unit
Remarks
40 EEPROM
information check
type
02H 0H
~
FFFFFFFFH
0: Disable checksum, 1: Enable checksum
Bit 0 = (For future expansion)
Bit 1 = Encoder
Bits 2 to 7 = (For future expansion)
0: Do not use EEPROM, 1: Use EEPROM
Bits 16 to 23 = (For future expansion)
41 Hardware
information check
type
0H 0H
~
FFFFFFFFH
Bits 0 = (For future expansion)
42
Hardware test type
0H
0H ~
FFFFFFFFH
Bits 0 to 2 = (For future expansion)
43
For future expansion
0H
0H ~
FFFFFFFFH
44 (For
expansion)
0
45 Special
start
condition setting
0 0H
~
FFFFFFFFH
Bits 0 to 3:
Enable start from PC/TP in AUTO mode = Used
exclusively by the manufacturer (0: Do not enable, 1:
Enable)
Bits 4 to 7:
PIO program start (Input port 000)
Single start selection (0: Normal, 1: Single start)
* In accordance with the input port for which the I/O
parameter “Input function selection” has been set to
“1” or “2.”
* When single start is selected, the next PIO program
start will not be accepted as long as a program with
the same program number as the one started by
the last PIO program start is running.
Bits 8 to 11:
Permission of auto program start when
all-operation-cancellation factor is present
(0: Do not permit, 1: Permit)
Bits 12 to 15: Permission of ON edge acceptance for PIO-program
start when all-operation-cancellation factor is present
(0: Do not permit, 1: Permit)
* In accordance with the input port for which the I/O
parameter “Input function selection” has been set to
“1” or “2.”
* This parameter specifies an ON-edge acceptance
condition. If the starting condition is not satisfied,
an “Error No. A1E: Start condition non-satisfaction
error” will generate.
46
Other setting bit
pattern 1
2011H 0H
~
FFFFFFFFH
Bits 0 to 3:
Variable-value format type in response message to
real-number/variable query
(0: Big endian with four upper/lower binary-converted
bytes reversed, 1: Big endian)
Bits 4 to 7:
Decimal-place rounding selection for real-number
o
integer-variable assignment in LET/TRAN
commands (0: Do not round, 1: Round)
Bits 8 to 11:
For future expansion
* Change strictly prohibited unless specified by the
manufacturer.
Bits 12 to 15: Selection of processing to be performed when
subroutine first step input condition is not specified
when TPCD command = 1
(0: Do not execute, 1: Execute, 2: Error)
47 ~
48
(For expansion)
0
Summary of Contents for PSEL
Page 2: ......
Page 10: ......
Page 18: ...8 Part 1 Installation ...
Page 37: ...27 Part 1 Installation 2 2 axis specification with battery ...
Page 382: ...372 Appendix Micro cylinder RCL Series Current limiting value ratio Push force N ...
Page 476: ...466 Appendix ...
Page 480: ...470 ...
Page 485: ...475 ...
Page 487: ...INTELLIGENT ACTUATOR SEL Language Programming Manual Eighth Edition ...
Page 488: ......
Page 490: ......
Page 494: ......
Page 518: ...24 ...
Page 526: ...32 ...
Page 831: ... 11 Actuator Control Declaration 337 Example DFIF 1 170 ...
Page 1060: ......
Page 1061: ......