[9] T
ask
Management
272
z
SSPG (Pause program)
Command, declaration
Extension
condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
E
N, Cnd
Cmnd
Operand 1
Operand 2
Pst
Optional Optional
SSPG
Program
number
(Program
number)
CC
Applicable models
All models [Refer to Section 5.1 for details of models]
{
[Function]
Pause the program from the one specified in operand 1 through the other specified
in operand 2, at the current step. Specification in operand 1 only is allowed.
(Note 1)
Pausing a program will also pause the operation the program has been executing.
(Note 2)
Not only the operation but also the execution of the step itself will be paused.
[Example 1]
SSPG
10
12
Pause program No. 10, 11 and 12 at the current step.
Error-generation/output-operation conditions
When one SSPG program is specified (only operand 1 is specified)
No program number error *1
Program already registered
Status of
the specified
program
Program running
Program not running
Program not yet
registered
Program number
error *1
Error None
None
C03
“Non-registered
program
specification error”
C2C
“Program number
error”
Output operation
ON
OFF
OFF
OFF
* The errors shown in the table represent those that generate in accordance with the status of the specified program.
Errors caused by other factors are excluded.
* 1… Program number error indicates specification of a number smaller than 1 or exceeding 64.
When multiple SSPG programs are specified (both operands 1 and 2 are specified)
No program number error *2
Registered program exists inside the specified range *3
Status of
the specified
program
Running program
exists inside the
specified range *4
None of programs
inside the specified
range are running
None of programs
inside the specified
range are
registered
Program number
error *1
Error None
None
C03
“Non-registered
program
specification error”
C2C
“Program number
error”
Output operation
ON
OFF
OFF
OFF
* The errors shown in the table represent those that generate in accordance with the status of the specified program.
Errors caused by other factors are excluded.
* 2… Program number error indicates specification of a number smaller than 1 or exceeding 64.
* 3… In this case, non-registered programs inside the specified range are not treated as a target of operation with
EXPG, ABPG, SSPG and PSPG commands. This will not affect error generation or output operation.
* 4… In this case, programs not running (but already registered) inside the specified range are not treated as a target of
operation with SSPG and RSPG commands. This will not affect error generation or output operation.
Program No. 10
Program No. 11
Program No. 12
Currently executed step
Currently executed step
Currently executed step
Summary of Contents for PSEL
Page 2: ......
Page 10: ......
Page 18: ...8 Part 1 Installation ...
Page 37: ...27 Part 1 Installation 2 2 axis specification with battery ...
Page 382: ...372 Appendix Micro cylinder RCL Series Current limiting value ratio Push force N ...
Page 476: ...466 Appendix ...
Page 480: ...470 ...
Page 485: ...475 ...
Page 487: ...INTELLIGENT ACTUATOR SEL Language Programming Manual Eighth Edition ...
Page 488: ......
Page 490: ......
Page 494: ......
Page 518: ...24 ...
Page 526: ...32 ...
Page 831: ... 11 Actuator Control Declaration 337 Example DFIF 1 170 ...
Page 1060: ......
Page 1061: ......