408
Appendix
1.2 I/O Function Lists
(1)
Input Function List
Input function
specification value
Function name
Remarks
0 General-purpose
input
1
Program start signal (BCD)
(ON edge)
Specify a BCD program number using the ports to which start-program number
specification bits x (input function specification values 9 through 15) are assigned.
* To ensure starting of the program, keep these bits ON for at least 100 msec.
* The following input functions cannot be assigned at the same time:
• Program start signal (BCD) (input function specification value = 1)
• Program start signal (BIN) (input function specification value = 2)
2
Program start signal (BIN)
(ON edge)
Specify a binary program number using the ports to which start-program number
specification bits x (input function specification values 9 through 15) are assigned.
* To ensure starting of the program, keep these bits ON for at least 100 msec.
* The following input functions cannot be assigned at the same time:
• Program start signal (BCD) (input function specification value = 1)
• Program start signal (BIN) (input function specification value = 2)
3
Soft reset signal (ON for 1
second)
If the emergency-stop recovery type is set to “Operation continued,” enable the soft
reset signal (to ensure the specified operation cancellation method will work.)
4
Servo ON
ON edge: Same as the all-valid-axes servo ON command
OFF edge: Same as the all-valid-axes servo OFF command (an interval of at least
1.5 seconds is required).
* The signal must be input when the actuator is not operating.
5 Auto-start
program
start
signal
ON edge: Start the program
OFF edge: Abort all operations/programs (excluding the I/O processing program at
operation/program abort)
* Turn ON the signal for at least 100 msec to ensure starting of the program.
6
Soft interlock for all servo
axes (OFF level)
Effective when the servo OFF command is not active. Operations will be put on hold
if the interlock signal is input during auto operation. Operations will be aborted if the
interlock signal is input during non-auto operation.
7
Operation-pause reset signal
(ON edge)
8
Operation pause signal (OFF
level)
Effective only during auto operation.
* Pause is reset using the operation-pause reset signal.
9 Start-program
number
specification bit 1 (least
significant bit)
* Start-program number specification bits x (input function setting values 9 through
15) cannot be assigned discontinuously from the LSB or in descending order from
the LSB (port numbers are not considered). Program No. 1 (BIN or BCD)
10 Start-program
number
specification bit 2
(Same as “Input function specification value = 9”) Program No. 2 (BIN or BCD)
11 Start-program
number
specification bit 3
(Same as “Input function specification value = 9”) Program No. 4 (BIN or BCD)
12 Start-program
number
specification bit 4
(Same as “Input function specification value = 9”) Program No. 8 (BIN or BCD)
13 Start-program
number
specification bit 5
(Same as “Input function specification value = 9”) Program No. 16 (BIN) or 10 (BCD)
14 Start-program
number
specification bit 6
(Same as “Input function specification value = 9”) Program No. 32 (BIN) or 20 (BCD)
15 Start-program
number
specification bit 7
(Same as “Input function specification value = 9”) Program No. 64 (BIN) or 40 (BCD)
16
Error reset (ON edge)
17
Drive-source cutoff reset input
(ON edge) (Effective when
the problem factor has been
removed)
Drive-source cutoff control is not available for axes whose motor-drive power source
is not installed in this controller, or axes whose drive-source cutoff circuit is not
controlled by this controller.
18
Home return command signal
for all valid axes (ON edge)
The servo must be turned on first (Input function specification value = 4, axis-specific
parameter No. 13)
19
Home return command signal
for all incremental axes (ON
edge)
The servo must be turned on first (Input function specification value = 4, axis-specific
parameter No. 13)
20 PC/TP-servo
movement
command acceptance
permission input
* Caution: Ineffective once operation is started.
21
Remote-mode control input
Is the specified DI is ON or the AUTO/MANU switch is set to “MANU,” the system
mode will become MANU.
* Debug filter is disabled on the remote-mode control input port.
22
Axis 1 forced brake-release
input
When the applicable port turns ON, the brake will be unlocked forcibly (pay attention
to falling load).
* Brake release of the synchronized slave axis conforms to brake release of the
synchronized master axis.
23
Axis 2 forced brake-release
input
When the applicable port turns ON, the brake will be unlocked forcibly (pay attention
to falling load).
* Brake release of the synchronized slave axis conforms to brake release of the
synchronized master axis.
24 ~ 27
For future expansion
Summary of Contents for PSEL
Page 2: ......
Page 10: ......
Page 18: ...8 Part 1 Installation ...
Page 37: ...27 Part 1 Installation 2 2 axis specification with battery ...
Page 382: ...372 Appendix Micro cylinder RCL Series Current limiting value ratio Push force N ...
Page 476: ...466 Appendix ...
Page 480: ...470 ...
Page 485: ...475 ...
Page 487: ...INTELLIGENT ACTUATOR SEL Language Programming Manual Eighth Edition ...
Page 488: ......
Page 490: ......
Page 494: ......
Page 518: ...24 ...
Page 526: ...32 ...
Page 831: ... 11 Actuator Control Declaration 337 Example DFIF 1 170 ...
Page 1060: ......
Page 1061: ......