146
Part 2 Programs
z
PAXS (Read axis pattern)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
Optional Optional
PAXS
Variable
number
Position
number
CP
[Function] Store the axis pattern at the position specified in operand 2 to the variable specified in
operand 1.
[Example 1]
PAXS
1
99
Read the axis pattern at position 99 to variable 1.
If the position is given as follows, “1” (binary 01) will be read
to variable 1.
[Example 2]
LET
1
3
Assign 3 to variable 1.
LET
2
101
Assign 101 to variable 2.
PAXS
*1
*2
Read the axis pattern at the content of variable 2 (position
101) to the content of variable 1 (variable 3).
If the point is given as follows, “3” (binary 11) will be stored
in variable 3.
The table below shows different positions and corresponding values stored in a variable.
Position data display in PC software
No. Axis1
Axis2
98
0 0 = 0 + 0 = 0
99 100.000
0 1 = 0 + 1 = 1
100
150.000
1 0 = 2 + 0 = 2
101 100.000
50.000
1 1 = 2 + 1 = 3
Summary of Contents for PSEL
Page 2: ......
Page 10: ......
Page 18: ...8 Part 1 Installation ...
Page 37: ...27 Part 1 Installation 2 2 axis specification with battery ...
Page 382: ...372 Appendix Micro cylinder RCL Series Current limiting value ratio Push force N ...
Page 476: ...466 Appendix ...
Page 480: ...470 ...
Page 485: ...475 ...
Page 487: ...INTELLIGENT ACTUATOR SEL Language Programming Manual Eighth Edition ...
Page 488: ......
Page 490: ......
Page 494: ......
Page 518: ...24 ...
Page 526: ...32 ...
Page 831: ... 11 Actuator Control Declaration 337 Example DFIF 1 170 ...
Page 1060: ......
Page 1061: ......