[27] Electronic Cam Control System
528
[Example]
XCAS
0
10
It starts to synchronize the electronic cam on axis 0. (*1)
XCAS
1
20
It starts to synchronize the electronic cam on axis 1. (*2)
MOVP 5
It moves the 1
st
axis of the main CPU control axes to
Position No. 5.
MOVP 6
It moves the 1
st
axis of the main CPU control axes to
Position No. 6.
XAXS
0
11
Set an axis pattern that uses axes 0 and 1.
XWIP
It waits till the positioning complete signal of axes 0 and
1 to turn ON. (Axes 0 and 1 continue the synchronizing
process.)
MOVP 7
It moves the 1
st
axis of the main CPU control axe to
Position No. 7.
* It is assumed the setting that the 1
st
axis of the main CPU control axes is
set to Variables No. 10 to 19 as the electronic cam synchronizing process
is established.
* It is assumed the setting that the 1
st
axis of the main CPU control axes is
set to Variables No. 20 to 29 as the electronic cam synchronizing process
is established.
Summary of Contents for PSEL
Page 2: ......
Page 10: ......
Page 18: ...8 Part 1 Installation ...
Page 37: ...27 Part 1 Installation 2 2 axis specification with battery ...
Page 382: ...372 Appendix Micro cylinder RCL Series Current limiting value ratio Push force N ...
Page 476: ...466 Appendix ...
Page 480: ...470 ...
Page 485: ...475 ...
Page 487: ...INTELLIGENT ACTUATOR SEL Language Programming Manual Eighth Edition ...
Page 488: ......
Page 490: ......
Page 494: ......
Page 518: ...24 ...
Page 526: ...32 ...
Page 831: ... 11 Actuator Control Declaration 337 Example DFIF 1 170 ...
Page 1060: ......
Page 1061: ......