427
Appendix
8. Manual
Operation
Types
The selectable operation types will vary depending on the setting of the “Manual operation type”
parameter (Other parameter No. 21).
(1) PC
software
[1] Setting = 0 (Always enable edit and SIO/PIO start)
Functions
Operation type
Password
Edit
Safety
speed
Jog, move,
continuous
move
SIO program
start
PIO program
start
With safety speed
Not required.
{
{
{
{
{
Without safety
speed
Not required.
{
{
{
{
[2] Setting = 1 (Select edit and start (with password))
Functions
Operation type
Password
Edit
Safety
speed
Jog, move,
continuous
move
SIO program
start
PIO program
start
Edit and jog
Not required.
{
{
{
SIO start and jog
(safety speed)
1817 (*1)
{
{
{
SIO start and jog
1818 (*1)
{
{
SIO/PIO start and
jog
1819 (*1)
{
{
{
(*1) PC software version 0.0.6.0 or later (“0000” in versions 0.0.0.0 through 0.0.5.x)
(2) Teaching
pendant
[1] Setting = 0 (Always enable edit and SIO/PIO start)
Functions
Safety-speed enable
selection
Password
Edit Safety
speed
Jog, move,
continuous
move
SIO program
start
PIO program
start
Enable Not
required.
{
{
{
{
{
Disable Not
required.
{
{
{
{
[2] Setting = 1 (Select edit and start (with password))
Functions
Safety-speed enable
selection
Password
Edit Safety
speed
Jog, move,
continuous
move
SIO program
start
PIO program
start
Enable Not
required.
{
{
{
{
(*3)
Disable 1818
(*1)
{
{
{
(*3)
Functions
PIO start
prohibition
selection
Password
Edit
Safety
speed
Jog, move,
continuous
move
SIO
program
start
PIO
program
start
Prohibit Not
required.
{
(*4)
{
{
Enable 1819
(*1)
{
(*4)
{
{
{
(*1) Teaching pendant application version 0.02 or later (not supported by version 0.01 or earlier)
(*2) PIO program start is enabled only in modes other than the edit mode.
(*3) In accordance with the “PIO start prohibition selection” setting.
(*4) In accordance with the “Safety-speed enable” setting.
*2
*2
Summary of Contents for PSEL
Page 2: ......
Page 10: ......
Page 18: ...8 Part 1 Installation ...
Page 37: ...27 Part 1 Installation 2 2 axis specification with battery ...
Page 382: ...372 Appendix Micro cylinder RCL Series Current limiting value ratio Push force N ...
Page 476: ...466 Appendix ...
Page 480: ...470 ...
Page 485: ...475 ...
Page 487: ...INTELLIGENT ACTUATOR SEL Language Programming Manual Eighth Edition ...
Page 488: ......
Page 490: ......
Page 494: ......
Page 518: ...24 ...
Page 526: ...32 ...
Page 831: ... 11 Actuator Control Declaration 337 Example DFIF 1 170 ...
Page 1060: ......
Page 1061: ......