67
Part 1 Installation
4. Drive-Source Recovery Request and Operation-Pause Reset Request
(1) Drive-source
recovery request
[1] Case where a drive-source request is required
A drive-source recovery request is required in the following case:
x
Specify a desired input port for receiving the drive-source cutoff reset input signal (dedicated
function).
Occurrence of a drive-source cutoff factor
o
Recovery after the cutoff factor is removed.
[2] How to request a drive-source recovery
A drive-source recovery request can be issued using one of the following methods:
x
Set the input function specification value “17” in the I/O parameter corresponding to the
desired input port number (Nos. 30 through 45, 251 through 258). (Refer to “I/O Function
Lists” and “I/O Parameters.”)
Input the ON edge to the input port of the specified number.
x
Select [Drive-Source Recovery Request (P)] from the [Controller (C)] menu on the PC
software screen.
x
Select Ctl (controller operation) and RPwr (drive-source recovery request) on the mode
selection screen of the teaching pendant.
(2) Operation-pause
reset
request
[1] Cases where an operation-pause reset request is required
An operation-pause reset request is required in any of the following cases:
x
An emergency stop was actuated during automatic operation when other parameter No. 10
was set to “2” (Emergency-stop recovery type = Continued operation) (only during automatic
operation)
o
Recovery (reset of operation pause) after the emergency stop is reset.
x
The automatic operation was stopped using the deadman switch or enable switch when other
parameter No. 11 was set to “2” (Deadman/enable switch recovery type = Continued
operation) (only during automatic operation)
o
Recovery (reset of operation pause) after the
stop is reset.
x
Specify a desired input port for receiving the operation-pause input signal (dedicated
function). Set the input function specification value “8” in the I/O parameter corresponding to
the desired input port number (Nos. 30 through 45, 251 through 258). (Refer to “I/O Function
Lists” and “I/O Parameters.”)
OFF level signal input is received by the import port of the specified number during auto
operation (operations pause)
o
Recovery after detection of ON signal level by the input port
(operation pause is reset).
[2] How to request an operation-pause reset
An operation-pause reset request can be issued using one of the following methods:
x
Specify a desired input port for receiving the operation-pause input signal (dedicated
function). Set the input function specification value “7” in the I/O parameter corresponding to
the desired input port number (Nos. 30 through 45, 251 through 258). (Refer to “I/O Function
Lists” and “I/O Parameters.”)
Input the ON edge to the input port of the specified number.
x
Select [Operation-Pause Reset Request (L)] from the [Controller (C)] menu on the PC
software screen.
x
Select Ctl (controller operation) and RAct (operation-pause reset request) on the mode
selection screen of the teaching pendant.
* If the case in [1] of (1) and any of the cases in [1] of (2) are present at the same time, a
drive-source recovery request must be issued first, followed by an operation-pause reset request.
Summary of Contents for PSEL
Page 2: ......
Page 10: ......
Page 18: ...8 Part 1 Installation ...
Page 37: ...27 Part 1 Installation 2 2 axis specification with battery ...
Page 382: ...372 Appendix Micro cylinder RCL Series Current limiting value ratio Push force N ...
Page 476: ...466 Appendix ...
Page 480: ...470 ...
Page 485: ...475 ...
Page 487: ...INTELLIGENT ACTUATOR SEL Language Programming Manual Eighth Edition ...
Page 488: ......
Page 490: ......
Page 494: ......
Page 518: ...24 ...
Page 526: ...32 ...
Page 831: ... 11 Actuator Control Declaration 337 Example DFIF 1 170 ...
Page 1060: ......
Page 1061: ......