[4] Logical Operation
244
[4] Logical
Operation
z
AND (Logical AND)
Command, declaration
Extension
condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
E
N, Cnd
Cmnd
Operand 1
Operand 2
Pst
Optional Optional AND
Variable
number
Data ZR
Applicable models
All models [Refer to Section 5.1 for details of models]
{
[Function]
Assign the logical AND operation result of the content of the variable specified in
operand 1 and the value specified in operand 2, to the variable specified in
operand 1.
The output will turn ON when the operation result becomes 0.
[Example 1]
LET
1
204
Assign 204 to variable 1.
AND
1
170
Assign the logical AND operation result (136) of the
content of variable 1 (204) and 170, to variable 1.
[Example 2]
LET
1
2
Assign 2 to variable 1.
LET
2
204
Assign 204 to variable 2.
LET
3
170
Assign 170 to variable 3.
AND
*1
*3
Assign the logical product 136 of the content 204 of
the variable that corresponds to the content of
variable 1, or 2, and the content of variable 3, or
170, to the variable that corresponds to the content
of variable 1, or 2.
Decimal
204
AND 170
136
Binary
11001100
AND 10101010
10001000
Summary of Contents for PSEL
Page 2: ......
Page 10: ......
Page 18: ...8 Part 1 Installation ...
Page 37: ...27 Part 1 Installation 2 2 axis specification with battery ...
Page 382: ...372 Appendix Micro cylinder RCL Series Current limiting value ratio Push force N ...
Page 476: ...466 Appendix ...
Page 480: ...470 ...
Page 485: ...475 ...
Page 487: ...INTELLIGENT ACTUATOR SEL Language Programming Manual Eighth Edition ...
Page 488: ......
Page 490: ......
Page 494: ......
Page 518: ...24 ...
Page 526: ...32 ...
Page 831: ... 11 Actuator Control Declaration 337 Example DFIF 1 170 ...
Page 1060: ......
Page 1061: ......