163
Part 2 Programs
z
DIS (Set division distance at spline movement)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
Optional Optional DIS
Distance
Prohibited CP
[Function] Set a division distance for the interpolation implemented by a PSPL (move along spline)
command.
When a PSPL command is executed, a passing point will be calculated at each distance set
here and the calculated passing points will be used as interpolation points.
If the distance is set to “0,” an appropriate division distance will be calculated automatically so
that the actuator will operate at the set speed
The distance is input in mm.
(Note)
If a PSPL command is executed without setting a distance with a DIS command, the default
value registered in “All-axis parameter No. 31, Default division distance” will be used.
[Example]
DIS
10
Set the division distance to 10 mm.
Interpolation points
Division distance
Summary of Contents for PSEL
Page 2: ......
Page 10: ......
Page 18: ...8 Part 1 Installation ...
Page 37: ...27 Part 1 Installation 2 2 axis specification with battery ...
Page 382: ...372 Appendix Micro cylinder RCL Series Current limiting value ratio Push force N ...
Page 476: ...466 Appendix ...
Page 480: ...470 ...
Page 485: ...475 ...
Page 487: ...INTELLIGENT ACTUATOR SEL Language Programming Manual Eighth Edition ...
Page 488: ......
Page 490: ......
Page 494: ......
Page 518: ...24 ...
Page 526: ...32 ...
Page 831: ... 11 Actuator Control Declaration 337 Example DFIF 1 170 ...
Page 1060: ......
Page 1061: ......