[3] Function Operation
243
z
SQR (Root operation)
Command, declaration
Extension
condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
E
N, Cnd
Cmnd
Operand 1
Operand 2
Pst
Optional Optional
SQR
Variable
number
Data ZR
Applicable models
All models [Refer to Section 5.1 for details of models]
{
[Function]
Assign the root of the data specified in operand 2 to the variable specified in
operand 1.
The output will turn ON when the operation result becomes 0.
[Example 1]
SQR
1
4
Assign the root of 4 (2) to variable 1.
[Example 2]
LET
1
10
Assign 10 to variable 1.
LET
2
4
Assign 4 to variable 2.
SQR
*1
*2
Assign the square root of the content of variable 2,
or 4, to the variable that corresponds to the content
of variable 1, or 10.
Summary of Contents for PSEL
Page 2: ......
Page 10: ......
Page 18: ...8 Part 1 Installation ...
Page 37: ...27 Part 1 Installation 2 2 axis specification with battery ...
Page 382: ...372 Appendix Micro cylinder RCL Series Current limiting value ratio Push force N ...
Page 476: ...466 Appendix ...
Page 480: ...470 ...
Page 485: ...475 ...
Page 487: ...INTELLIGENT ACTUATOR SEL Language Programming Manual Eighth Edition ...
Page 488: ......
Page 490: ......
Page 494: ......
Page 518: ...24 ...
Page 526: ...32 ...
Page 831: ... 11 Actuator Control Declaration 337 Example DFIF 1 170 ...
Page 1060: ......
Page 1061: ......