2. Connection with Host System
102
[2] Virtual I/O Port
Virtual I/O ports are provided so that the controller can notify internal information. They are
used to warn a low power-supply voltage, notify errors, etc. Use these ports as necessary.
TT/TTA Virtual Input Ports (Internal Flags)
Port No.
Function
7000 Always
OFF
7001 Always
ON
7002
System-memory backup battery voltage low warning
(Note TTA is for system reservation)
7003
System-memory backup battery voltage error
(Note TTA is for system reservation)
7004
Reserved by the system = Use is prohibited
7005
Reserved by the system = Use is prohibited
7006
Critical system error = A message level error is present.
7007
Critical system error = An operation-cancellation level error is present.
7008
Critical system error = A cold-start level error is present.
7009
Reserved by the system = Use is prohibited
7010
A cause of drive-source cutoff is present (including a condition waiting for a cutoff cancellation input).
7011
A latch signal indicating that a cause of all-operation cancellation is present.
(This latch signal is used to recognize a cause of 1-shot reset. Latch cancellation: 7300-ON)
7012
A cause of all-operation pause is present (including a condition waiting for the restart switch to be pressed).
(Effective only in the auto operation recognition mode)
7013
A cause of all-servo-axis interlock is present (cause of all-operation pause + cause of interlock input port)
7014 to 7050 Reserved by the system = Use is prohibited
7051 to 7070 For future expansion = Use is prohibited
7071
In the AUTO mode
7072
During auto operation
7073 to 7100 Reserved by the system = Use is prohibited
7101
Program No. 01 is being executed (or paused).
~
~
(Note TTA : Port No.7101 to 7228, program No.1 to 128 are being executed.)
7164
Program No. 64 is being executed (or paused).
7165 to 7299 For future expansion = Use is prohibited
TT Virtual Output Ports (Internal Flags)
Port No.
Function
7300
A latch cancellation signal is output to cancel the latch signal indicating a cause of all-operation cancellation
(7011). (Unlatched only when the cause of operation cancellation is no longer present.)
(7300 is turned OFF after latch cancellation is attempted.)
7301 to 7380 (For future expansion = Use is strictly prohibited)
7381 to 7399 (Reserved by the system = Use is strictly prohibited)
7400 to 7599 (For future expansion = Use is strictly prohibited)
(Note TTA : Port No.7401 to 7527, Program No.129 to 255
are being executed.)
Summary of Contents for PSEL
Page 2: ......
Page 10: ......
Page 18: ...8 Part 1 Installation ...
Page 37: ...27 Part 1 Installation 2 2 axis specification with battery ...
Page 382: ...372 Appendix Micro cylinder RCL Series Current limiting value ratio Push force N ...
Page 476: ...466 Appendix ...
Page 480: ...470 ...
Page 485: ...475 ...
Page 487: ...INTELLIGENT ACTUATOR SEL Language Programming Manual Eighth Edition ...
Page 488: ......
Page 490: ......
Page 494: ......
Page 518: ...24 ...
Page 526: ...32 ...
Page 831: ... 11 Actuator Control Declaration 337 Example DFIF 1 170 ...
Page 1060: ......
Page 1061: ......