Part 2 Programs
z
PAPR (Set push-motion approach distance, speed)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
Optional Optional
PAPR
Distance
Speed CP
[Function] Set the operation to be performed when a PUSH command is executed.
Set the distance (push-motion approach distance) over which push-motion approach
operation (torque-limiting operation) will be performed in operand 1 (in mm), and set the
speed (push-motion approach speed) at which push-motion approach operation
(torque-limiting operation) will be performed in operand 2 (in mm/sec).
The push-motion approach distance specified in operand 1 may contain up to three decimal
places, while the speed specified in operand 2 cannot contain any decimal place.
[Example]
PAPR
100
30
Set the push-motion approach distance in a PUSH
command to 100 mm and the push-motion approach speed
to 30 mm/sec.
MOVP
2
Move to position No. 2.
PUSH
10
Move by push motion from position No. 2 to position No. 10.
(Note)
The push-motion approach speed in an OVRD command will be clamped by the minimum speed
of 1 mm/sec. (Correct push-motion operation is not guaranteed at the minimum speed.
Operation at slow push-motion approach must be checked on the actual machine by considering
the effects of mechanical characteristics, etc.)
Y-axis
Position origin
Push-motion approach distance
Target position
X-axis
Start position of push-motion approach operation
(torque-limiting operation)
Summary of Contents for PSEL
Page 2: ......
Page 10: ......
Page 18: ...8 Part 1 Installation ...
Page 37: ...27 Part 1 Installation 2 2 axis specification with battery ...
Page 382: ...372 Appendix Micro cylinder RCL Series Current limiting value ratio Push force N ...
Page 476: ...466 Appendix ...
Page 480: ...470 ...
Page 485: ...475 ...
Page 487: ...INTELLIGENT ACTUATOR SEL Language Programming Manual Eighth Edition ...
Page 488: ......
Page 490: ......
Page 494: ......
Page 518: ...24 ...
Page 526: ...32 ...
Page 831: ... 11 Actuator Control Declaration 337 Example DFIF 1 170 ...
Page 1060: ......
Page 1061: ......