5. SEL
Commands
222
5.2 SEL Language Code Table for each Function
For Operand 1, Operand 2 and the output, the variable indirect specification is available.
For the condition, Operand 1, Operand 2 and the output, an input with symbols is available.
Input into ( ) for Operand 1 and Operand 2 is not compulsory.
“Actuator control declaration” command is kept effective though the program run once it is
executed during the program. A reconstruction of the settings is required for the appropriate
areas in the program if a change to the values (Operand 1, Operand 2, etc.) already set by
“actuator control declaration” command is needed. It means that the values set by the
executed command in the last operation are effective.
The output section is turned OFF when the command is executed. After the command
execution, it may get turned ON depending on the condition of the output section operation
type. (It is turned OFF if the condition does not meet the requirement.)
Caution: Comparative command CP
(CPEQ, CPNE, CPGT, CPGE, CPLT, CPLE) output
section does not get turned OFF during the command execution.
Output operation types
CC: Command successful, ZR: Calculation result zero
PE: Operation complete, CP: Command passing, TU: Timeout
EQ: Operand 1 = Operand 2, NE: Operand 1
#
Operand 2
GT: Operand 1 > Operand 2, GE: Operand 1
t
Operand 2
LT: Operand 1 < Operand 2, LE: Operand 1
d
Operand 2
Category Condition Command
Operand 1
Operand 2
Output
Function
Page
Optional
LET
Variable Assignment
Assignment number
ZR
Assign
231
Optional TRAN Variable
to
copy
data
to Variable to copy data from
ZR Copy
232
Variable
Assignmen
t
Optional
CLR
Clear start variable
Clear finish variable
ZR
Clear variable
233
Optional ADD Augend
variable
Addend
ZR Add
234
Optional SUB Minuend
variable
Subtrahend
ZR Subtract
235
Optional MULT Multiplicand
variable Multiplier
ZR Multiply
236
Optional DIV Dividend
variable
Divisor
ZR Divide
237
Arithme
tic
Operati
on
Optional MOD
Modulus assignment
variable
Divisor ZR
Modulus calculation
238
Optional SIN Sine assignment variable Operant [Radian]
ZR
Sine
239
Optional COS
Cosine assignment
variable
Operant [Radian]
ZR
Cosine
240
Optional TAN
Tangent assignment
variable
Operant [Radian]
ZR
Tangent
241
Optional ATN
Arc tangent assignment
variable
Operant ZR
Inverse-tangent
242
Functio
n
O
p
era
tion
Optional SQR
Square root assignment
variable
Operant ZR
Root
243
Optional AND
Logical conjunction
variable
Operant ZR
Logical
AND
244
Optional OR
Logical disjunction
variable
Operant ZR
Logical
OR
245
Logical
Operati
on
Optional EOR
Logical operation
exclusive disjunction
Operant ZR
Logical
exclusive-OR
246
Comparison
Optional CP
Comparative variable
Compared number
EQ NE GT
GE LT LE
Compare [EQ/NE/GT/GE/LT/LE] 247
Optional
TIMW
Waiting time [sec]
Prohibited
TU
Wait for certain time
248
Optional TIMC Program
No.
Prohibited
CP Cancel
waiting
249
Timer
Optional GTTM
Time assignment
variable
Prohibited CP
Get time
250
Optional BT
Start output, Flag
(Complete output, Flag)
CP
Output, flag [ON/OF/NT]
251
Optional
BTPN
Output port, Flag
Timer setting
CP
Output ON pulse
252
Optional
BTPF
Output port, Flag
Timer setting
CP
Output OFF pulse
253
Optional WT
I/O, Flag
(Waiting time)
TU
Wait for input and output, flag [ON/OF]
254
Optional
IN
Head I/O, Flag
Complete input and
output, Flag
CC
Input binary number (Max 32 bit)
255
Optional
INB
Head I/O, Flag
Convertible digits
CC
Input BCD (Max eight digits)
256
Optional
OUT
Head output, Flag
Complete input and
output, Flag
CC
Output binary number (Max 32 bit)
257
Optional
OTPS Output port No.
Axis No.
CC
Output current position data
263
Optional
OUTB Head output, Flag
Convertible digits
CC
Output BCD (Max eight digits)
258
I/O
, Flag O
pera
tion
Optional
FMIO
Format type
Prohibited
CP
IN (B) OUT (B) command format
259
Summary of Contents for PSEL
Page 2: ......
Page 10: ......
Page 18: ...8 Part 1 Installation ...
Page 37: ...27 Part 1 Installation 2 2 axis specification with battery ...
Page 382: ...372 Appendix Micro cylinder RCL Series Current limiting value ratio Push force N ...
Page 476: ...466 Appendix ...
Page 480: ...470 ...
Page 485: ...475 ...
Page 487: ...INTELLIGENT ACTUATOR SEL Language Programming Manual Eighth Edition ...
Page 488: ......
Page 490: ......
Page 494: ......
Page 518: ...24 ...
Page 526: ...32 ...
Page 831: ... 11 Actuator Control Declaration 337 Example DFIF 1 170 ...
Page 1060: ......
Page 1061: ......